BIAXIAL EXCITATION GENERATOR (BEGA) – 9 PHASES OPERATION IN FAULTY CONDITIONS

This paper presents a biaxial excitation generator for automobiles (BEGA) in generator mode, three three-phase windings (9 phases), and three diode bridge rectifiers DC parallel-connected for full power. BEGA is a synchronous machine with a biaxial excitation: one along the d-axis produced by the DC excitation coils (fed through brushes or contactless) and another along the q-axis produced by the PMs. The experimental demonstration of fault-tolerant characteristics was conducted under various fault conditions, including interrupted phases, short-circuited coils, and missing or short-circuited diodes. The importance of having all three three-phase windings (star-connection) connected in neutral points is highlighted and discussed. A comprehensive analysis of the impact of these faults on the harmonic spectrum is presented using a fast Fourier transform.

Authors

Institutions

Publication Details

Journal
REVUE ROUMAINE DES SCIENCES TECHNIQUES — SÉRIE ÉLECTROTECHNIQUE ET ÉNERGÉTIQUE
Published
2025-03-25
DOI
https://doi.org/10.59277/rrst-ee.2025.1.7
Primary Topic
Oil and Gas Production Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

BIAXIAL EXCITATION GENERATOR (BEGA) – 9 PHASES OPERATION IN FAULTY CONDITIONS

Liviu-Dănuț Vitan, Adrian Daniel Martin, Ion Boldea, Lucian Tutelea
1 links
REVUE ROUMAINE DES SCIENCES TECHNIQUES — SÉRIE ÉLECTROTECHNIQUE ET ÉNERGÉTIQUE
Oil and Gas Production Techniques
article

BIAXIAL EXCITATION GENERATOR (BEGA) – 9 PHASES OPERATION IN FAULTY CONDITIONS

Liviu-Dănuț Vitan, Adrian Daniel Martin, Ion Boldea, Lucian Tutelea
article en

Abstract

This paper presents a biaxial excitation generator for automobiles (BEGA) in generator mode, three three-phase windings (9 phases), and three diode bridge rectifiers DC parallel-connected for full power. BEGA is a synchronous machine with a biaxial excitation: one along the d-axis produced by the DC excitation coils (fed through brushes or contactless) and another along the q-axis produced by the PMs. The experimental demonstration of fault-tolerant characteristics was conducted under various fault conditions, including interrupted phases, short-circuited coils, and missing or short-circuited diodes. The importance of having all three three-phase windings (star-connection) connected in neutral points is highlighted and discussed. A comprehensive analysis of the impact of these faults on the harmonic spectrum is presented using a fast Fourier transform.

REVUE ROUMAINE DES SCIENCES TECHNIQUES — SÉRIE ÉLECTROTECHNIQUE ET ÉNERGÉTIQUEVol. 70(1)
Polytechnic University of Timişoara (RO)
Openalex Percentile: Top 92%
Oil and Gas Production Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.