The Threat of Moisture in the Partitions of Unheated and Heated Wooden Historic Churches in Poland

This paper presents experimental studies of the formation of thermal and humidity conditions in two wooden historic churches in southern Poland. The environmental and cultural changes taking shape are creating the need to modernize existing buildings to sustainable standards. The modernization of historic religious buildings is complicated by restrictions on the intrusion of vertical partitions, which are often covered with valuable wall paintings. The paper focuses on the important aspect of preserving historically valuable buildings in good condition and assessing the threat posed by vapor condensation on the surface of the partitions. The studied buildings differ in terms of their uses and heating systems. Building A is unheated, while building B is equipped with a heating system. The scope of the study includes continuous measurements of the temperature and relative humidity of the indoor air inside and outside the studied churches. The work presents a detailed analysis and comparison of the formation of thermal and humidity conditions inside the churches. A computational model of the buildings was created, and then a computational simulation of the risk of water vapor condensation on the surface of the external walls was carried out. The analysis presents the influence of the external climate on the formation of the thermo-humidity conditions inside the buildings, especially in the unheated church. Also shown is the effect of the temporary heating of the church on ensuring the optimal heat and moisture conditions for historic wooden buildings. The analysis shows that turning on the heating only during the use of the church slightly improves the thermal and humidity conditions compared to the unheated church. Additionally, the analysis shows that the occasional use of the unheated church contributes to significant cooling of the church (even to −8.4 °C in the winter half year). Another conclusion that the computational analysis reveals is that water vapor condensation on the surface of the external walls is impossible. However, the difference between the air temperature in the church and the dew point temperature, specifically in the unheated church, is 1.6 °C. Therefore, at lower outside air temperatures, there may be a risk of water vapor condensation.

Authors

Institutions

Publication Details

Journal
Sustainability
Published
2025-03-26
DOI
https://doi.org/10.3390/su17072941
Primary Topic
Conservation Techniques and Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Threat of Moisture in the Partitions of Unheated and Heated Wooden Historic Churches in Poland

Grzegorz Nawalany, Paweł Sokołowski, Małgorzata Michalik, Elżbieta Michalik et al.
Sustainability
Conservation Techniques and Studies
article

The Threat of Moisture in the Partitions of Unheated and Heated Wooden Historic Churches in Poland

Grzegorz Nawalany, Paweł Sokołowski, Małgorzata Michalik, Elżbieta Michalik, Zbigniew Lofek
article en

Abstract

This paper presents experimental studies of the formation of thermal and humidity conditions in two wooden historic churches in southern Poland. The environmental and cultural changes taking shape are creating the need to modernize existing buildings to sustainable standards. The modernization of historic religious buildings is complicated by restrictions on the intrusion of vertical partitions, which are often covered with valuable wall paintings. The paper focuses on the important aspect of preserving historically valuable buildings in good condition and assessing the threat posed by vapor condensation on the surface of the partitions. The studied buildings differ in terms of their uses and heating systems. Building A is unheated, while building B is equipped with a heating system. The scope of the study includes continuous measurements of the temperature and relative humidity of the indoor air inside and outside the studied churches. The work presents a detailed analysis and comparison of the formation of thermal and humidity conditions inside the churches. A computational model of the buildings was created, and then a computational simulation of the risk of water vapor condensation on the surface of the external walls was carried out. The analysis presents the influence of the external climate on the formation of the thermo-humidity conditions inside the buildings, especially in the unheated church. Also shown is the effect of the temporary heating of the church on ensuring the optimal heat and moisture conditions for historic wooden buildings. The analysis shows that turning on the heating only during the use of the church slightly improves the thermal and humidity conditions compared to the unheated church. Additionally, the analysis shows that the occasional use of the unheated church contributes to significant cooling of the church (even to −8.4 °C in the winter half year). Another conclusion that the computational analysis reveals is that water vapor condensation on the surface of the external walls is impossible. However, the difference between the air temperature in the church and the dew point temperature, specifically in the unheated church, is 1.6 °C. Therefore, at lower outside air temperatures, there may be a risk of water vapor condensation.

SustainabilityVol. 17(7)
University of Agriculture in Krakow (PL)
Openalex Percentile: Top 93%
Conservation Techniques and Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.