Overcurrent Limitation and Enhanced Fault Current Utilization by Grid-Forming Inverter Using Hybrid Methods During Short Circuit Faults

The next-generation grid-forming (GFM) inverters face significant over-current and over-voltage challenges during grid faults due to their inherent voltage source behaviour behind impedance. These challenges are mitigated by simultaneously reconstructing power, voltage, or current references fed to different control layers in a coordinated way, known as the hybrid method. However, existing hybrid methods fail to 1) ensure maximum fault current utilization and 2) provide improved post-fault recovery. This paper proposes two new hybrid methods to address these limitations. The first method employs a novel non-linear transient virtual resistance (NLTVR) combined with reconstructed power references for symmetrical faults. An extension of NLTVR, referred to as unified NLTVR (UNLTVR), is introduced to handle both symmetrical and asymmetrical faults. By integrating NLTVR or UNLTVR with reconstructed power references based on grid fault severity, the inverter operates near its maximum current limit during faults while preserving GFM functionality, ensuring smooth post-fault power recovery without exceeding reference values. The second method combines the sinusoidal current reference limiter (SCRL) with the proposed UNLTVR. The proposed schemes are implemented in a droop-controlled GFM inverter modelled in the stationary reference frame. The effectiveness of the proposed methods is demonstrated through MATLAB/Simulink simulations of symmetrical and asymmetrical faults, supported by a Controller Hardware-in-the-Loop (CHIL) experiment. The proposed methods are also compared with conventional current-limiting methods. It is revealed that the SCRL achieves maximum fault current capability faster, while the combined efforts of the UNLTVR help the GFM inverter to experience a seamless post-fault recovery.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3555817
Citations
2
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
1.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Overcurrent Limitation and Enhanced Fault Current Utilization by Grid-Forming Inverter Using Hybrid Methods During Short Circuit Faults

Jack Benjamin, Pratyasa Bhui, Animesh Sahoo
2 citations
IEEE Access
HVDC Systems and Fault Protection
1.46
article

Overcurrent Limitation and Enhanced Fault Current Utilization by Grid-Forming Inverter Using Hybrid Methods During Short Circuit Faults

Jack Benjamin, Pratyasa Bhui, Animesh Sahoo
article en
2 citations

Abstract

The next-generation grid-forming (GFM) inverters face significant over-current and over-voltage challenges during grid faults due to their inherent voltage source behaviour behind impedance. These challenges are mitigated by simultaneously reconstructing power, voltage, or current references fed to different control layers in a coordinated way, known as the hybrid method. However, existing hybrid methods fail to 1) ensure maximum fault current utilization and 2) provide improved post-fault recovery. This paper proposes two new hybrid methods to address these limitations. The first method employs a novel non-linear transient virtual resistance (NLTVR) combined with reconstructed power references for symmetrical faults. An extension of NLTVR, referred to as unified NLTVR (UNLTVR), is introduced to handle both symmetrical and asymmetrical faults. By integrating NLTVR or UNLTVR with reconstructed power references based on grid fault severity, the inverter operates near its maximum current limit during faults while preserving GFM functionality, ensuring smooth post-fault power recovery without exceeding reference values. The second method combines the sinusoidal current reference limiter (SCRL) with the proposed UNLTVR. The proposed schemes are implemented in a droop-controlled GFM inverter modelled in the stationary reference frame. The effectiveness of the proposed methods is demonstrated through MATLAB/Simulink simulations of symmetrical and asymmetrical faults, supported by a Controller Hardware-in-the-Loop (CHIL) experiment. The proposed methods are also compared with conventional current-limiting methods. It is revealed that the SCRL achieves maximum fault current capability faster, while the combined efforts of the UNLTVR help the GFM inverter to experience a seamless post-fault recovery.

IEEE AccessVol. 13
Indian Institute of Technology Dharwad (IN)
Affordable and clean energy
Openalex Percentile: Top 19%
HVDC Systems and Fault Protection
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.