Analysis of Partial Discharges in Oil-Impregnated Transformer Paper Insulation and PET-G Insulation

Partial discharge (PD) is a widespread phenomenon instigated in power transformer (PT) insulation systems. PDs are triggered by voids that vary in size and position within the PT insulation. The electrical characteristics of those damaging, PD-causing cavities must be well understood, to accelerate the development of advanced PD detection techniques. Thus, the impact of varying the radius and position of spherical air voids on the characteristics of PDs in PTs is examined using a 3-D finite element analysis (FEA) model designed in COMSOL Multiphysics. The spherical voids are positioned between two windings of a 512 kV, three-phase (3<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\varphi $ </tex-math></inline-formula>) PT. The peak electric field (EF) and aggregate energy in the FEA model are used in conjunction with laboratory measurements of the apparent discharge magnitude, for detailed analysis of Polyethylene Terephthalate Glycol (PET-G)-based cylindrical voids with different heights. Simulations demonstrate that the inception of PD activity in the PT model occurs for spherical voids with a radius exceeding 1 mm. Furthermore, the most severe PDs occur within the press-board insulation, adjacent to the uppermost part of the innermost windings. Experiments demonstrate that a significant increase in PD activity was observed for PET-G-based cylindrical voids with heights exceeding 1 mm.

Authors

Institutions

Publication Details

Journal
IEEE Open Journal of Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/ojim.2025.3555323
Citations
2
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
1.04

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Partial Discharges in Oil-Impregnated Transformer Paper Insulation and PET-G Insulation

Haitham Abu‐Rub, Ali Ghrayeb, Marek Olesz, Shady S. Refaat et al.
2 citations
IEEE Open Journal of Instrumentation and Measurement
High voltage insulation and dielectric phenomena
1.04
article

Analysis of Partial Discharges in Oil-Impregnated Transformer Paper Insulation and PET-G Insulation

Haitham Abu‐Rub, Ali Ghrayeb, Marek Olesz, Shady S. Refaat, Mohammad AlShaikh Saleh, Sayed Mohammad Kameli, Abdelaziz Abuelrub
article en
2 citations

Abstract

Partial discharge (PD) is a widespread phenomenon instigated in power transformer (PT) insulation systems. PDs are triggered by voids that vary in size and position within the PT insulation. The electrical characteristics of those damaging, PD-causing cavities must be well understood, to accelerate the development of advanced PD detection techniques. Thus, the impact of varying the radius and position of spherical air voids on the characteristics of PDs in PTs is examined using a 3-D finite element analysis (FEA) model designed in COMSOL Multiphysics. The spherical voids are positioned between two windings of a 512 kV, three-phase (3<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\varphi $ </tex-math></inline-formula>) PT. The peak electric field (EF) and aggregate energy in the FEA model are used in conjunction with laboratory measurements of the apparent discharge magnitude, for detailed analysis of Polyethylene Terephthalate Glycol (PET-G)-based cylindrical voids with different heights. Simulations demonstrate that the inception of PD activity in the PT model occurs for spherical voids with a radius exceeding 1 mm. Furthermore, the most severe PDs occur within the press-board insulation, adjacent to the uppermost part of the innermost windings. Experiments demonstrate that a significant increase in PD activity was observed for PET-G-based cylindrical voids with heights exceeding 1 mm.

IEEE Open Journal of Instrumentation and MeasurementVol. 4
University of Hertfordshire (GB), Hamad bin Khalifa University (QA), Texas A&M University at Qatar (QA), Texas A&M University (US), Qatar Foundation (QA)
Qatar National Research Fund
Openalex Percentile: Top 27%
High voltage insulation and dielectric phenomena
1.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.