Computational Fluid Dynamics Analysis of an Office With Seated Persons and a Double-Duct Solar Roof Chimney for Passive Ventilation

Abstract This investigation reports a detailed computational study of heat transfer and airflow in an office with seated persons with a double-duct vertical roof solar chimney (SC). The computational model was validated with experimental temperature profiles. The validated computational model was used to analyze the effect of the heating of the SC and one vertical wall of the room on temperature fields, flow patterns, and the draught rate (DR) (discomfort index) in the thermal system. According to the Standard 62.1 of the American National Standards Institute (ANSI) and the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), the present arrangement is adequate for the ventilation of offices. According to DR values, in offices with seated persons, the use of solar chimneys offers a natural and comfortable ventilation alternative, causing the removal and exchange of air, thereby improving the entry of air without compromising comfort conditions.

Authors

Institutions

Publication Details

Journal
Journal of Solar Energy Engineering
Published
2025-03-28
DOI
https://doi.org/10.1115/1.4068306
Primary Topic
Solar Energy Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Computational Fluid Dynamics Analysis of an Office With Seated Persons and a Double-Duct Solar Roof Chimney for Passive Ventilation

J.F. Hinojosa, A García Vázquez, J. M. A. Navarro
Journal of Solar Energy Engineering
Solar Energy Systems and Technologies
article

Computational Fluid Dynamics Analysis of an Office With Seated Persons and a Double-Duct Solar Roof Chimney for Passive Ventilation

J.F. Hinojosa, A García Vázquez, J. M. A. Navarro
article en

Abstract

Abstract This investigation reports a detailed computational study of heat transfer and airflow in an office with seated persons with a double-duct vertical roof solar chimney (SC). The computational model was validated with experimental temperature profiles. The validated computational model was used to analyze the effect of the heating of the SC and one vertical wall of the room on temperature fields, flow patterns, and the draught rate (DR) (discomfort index) in the thermal system. According to the Standard 62.1 of the American National Standards Institute (ANSI) and the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), the present arrangement is adequate for the ventilation of offices. According to DR values, in offices with seated persons, the use of solar chimneys offers a natural and comfortable ventilation alternative, causing the removal and exchange of air, thereby improving the entry of air without compromising comfort conditions.

Journal of Solar Energy EngineeringVol. 147(4)
Universidad de Sonora (MX), Tecnológico Nacional de México (MX), Instituto Tecnológico de Hermosillo (MX)
Openalex Percentile: Top 94%
Solar Energy Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.