A New Approach to Determine Feasible Operating Region of Unbalanced Distribution Networks With Distributed Photovoltaics

Amidst rising distributed generation and its potential role in grid management, this article presents a new realistic approach to determine the operational space and flexibility potential of an unbalanced active distribution network. The feasible operating region of an active distribution network is constituted by its range of active-reactive power exchanges with the bulk power system without breaching network constraints. This study explores the potential of highly penetrated single- and three-phase distributed photovoltaics and voltage-sensitive loads to determine the feasible operating region at different operating points. The cumulative response of Volt-Var controlled distributed photovoltaics and voltage-sensitive loads determines the power flow at the bulk power system-active distribution network interconnection, ensuring feasibility with respect to voltage magnitude and unbalance constraints. Further, the correspondence of feasible operating region with the tap-settings of substation transformer enables a novel feature to traverse throughout the available operating region and facilitate bulk power system-active distribution network power coordination. Additionally, a nodal sensitivity-based adjustable Volt-Var control scheme is proposed for distributed photovoltaics, improving the feasible operating region. The proposed strategy is validated on bulk power system-active distribution network integrated test system. Bulk power system: IEEE-9 bus system – Active distribution network: (highly unbalanced IEEE-13 bus distribution system (medium voltage) + modified CIGRE low voltage system).

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Power Delivery
Published
2025-03-28
DOI
https://doi.org/10.1109/tpwrd.2025.3555210
Citations
11
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
8.03
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A New Approach to Determine Feasible Operating Region of Unbalanced Distribution Networks With Distributed Photovoltaics

Reza Razzaghi, Zakir Hussain Rather, Manorath Prasad, Suryanarayana Doolla
11 citations
IEEE Transactions on Power Delivery
Power Systems and Technologies
8.03
article

A New Approach to Determine Feasible Operating Region of Unbalanced Distribution Networks With Distributed Photovoltaics

Reza Razzaghi, Zakir Hussain Rather, Manorath Prasad, Suryanarayana Doolla
article en
11 citations

Abstract

Amidst rising distributed generation and its potential role in grid management, this article presents a new realistic approach to determine the operational space and flexibility potential of an unbalanced active distribution network. The feasible operating region of an active distribution network is constituted by its range of active-reactive power exchanges with the bulk power system without breaching network constraints. This study explores the potential of highly penetrated single- and three-phase distributed photovoltaics and voltage-sensitive loads to determine the feasible operating region at different operating points. The cumulative response of Volt-Var controlled distributed photovoltaics and voltage-sensitive loads determines the power flow at the bulk power system-active distribution network interconnection, ensuring feasibility with respect to voltage magnitude and unbalance constraints. Further, the correspondence of feasible operating region with the tap-settings of substation transformer enables a novel feature to traverse throughout the available operating region and facilitate bulk power system-active distribution network power coordination. Additionally, a nodal sensitivity-based adjustable Volt-Var control scheme is proposed for distributed photovoltaics, improving the feasible operating region. The proposed strategy is validated on bulk power system-active distribution network integrated test system. Bulk power system: IEEE-9 bus system – Active distribution network: (highly unbalanced IEEE-13 bus distribution system (medium voltage) + modified CIGRE low voltage system).

IEEE Transactions on Power DeliveryVol. 40(3)
Indian Institute of Technology Bombay (IN), Monash University (AU)
Affordable and clean energy
Openalex Percentile: Top 2%
Power Systems and Technologies
8.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.