Dual Transformer Network for Predicting Joint Angles and Torques From Multi-Channel EMG Signals in the Lower Limbs

Accurate estimation of lower limb joint kinematics and kinetics using wearable sensors enables biomechanical analysis beyond laboratory settings and facilitates real-time adaptation of exoskeleton assistance profiles. This study introduces a Dual Transformer Network (DTN) designed to concurrently estimate multiple joint angles and moments from multi-channel surface electromyography (sEMG) signals in the lower limbs. The performance evaluation of the predicted joint angles for the hip, knee, and ankle showed average root mean square error (RMSE) values of 1.1827, 1.4312, and 0.8113, Pearson correlation coefficients () of 0.9992, 0.9993, and 0.9991, and coefficients of determination () of 0.9847, 0.9858, and 0.9838, respectively. For the predicted joint moments, the corresponding values were RMSE of 0.0458, 0.0341, and 0.0522 Nm/kg, of 0.9978, 0.9972, and 0.9990, and of 0.9825, 0.9801, and 0.9902. Angular velocities, derived by differentiating the estimated joint angles, achieved an RMSE below 0.6530 rd/s, exceeding 0.9534, and above 0.9552. Additionally, joint power, computed as the dot product of predicted joint moments and angular velocities, resulted in RMSE below 0.3823W/kg, above 0.9771, and above 0.8925. These results demonstrate the effectiveness of the proposed network in continuously estimating lower limb kinematics and kinetics, contributing to advancements in assist-as-needed exoskeleton control strategies.

Authors

Institutions

Publication Details

Journal
IEEE Journal of Biomedical and Health Informatics
Published
2025-01-01
DOI
https://doi.org/10.1109/jbhi.2025.3555255
Citations
9
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
6.07

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual Transformer Network for Predicting Joint Angles and Torques From Multi-Channel EMG Signals in the Lower Limbs

Yang Zhou, Chunjie Chen, Xinyu Wu, Zhuo Wang et al.
9 citations
IEEE Journal of Biomedical and Health Informatics
Muscle activation and electromyography studies
6.07
article

Dual Transformer Network for Predicting Joint Angles and Torques From Multi-Channel EMG Signals in the Lower Limbs

Yang Zhou, Chunjie Chen, Xinyu Wu, Zhuo Wang, Xiangyang Wang, Hui Chen
article en
9 citations

Abstract

Accurate estimation of lower limb joint kinematics and kinetics using wearable sensors enables biomechanical analysis beyond laboratory settings and facilitates real-time adaptation of exoskeleton assistance profiles. This study introduces a Dual Transformer Network (DTN) designed to concurrently estimate multiple joint angles and moments from multi-channel surface electromyography (sEMG) signals in the lower limbs. The performance evaluation of the predicted joint angles for the hip, knee, and ankle showed average root mean square error (RMSE) values of 1.1827, 1.4312, and 0.8113, Pearson correlation coefficients () of 0.9992, 0.9993, and 0.9991, and coefficients of determination () of 0.9847, 0.9858, and 0.9838, respectively. For the predicted joint moments, the corresponding values were RMSE of 0.0458, 0.0341, and 0.0522 Nm/kg, of 0.9978, 0.9972, and 0.9990, and of 0.9825, 0.9801, and 0.9902. Angular velocities, derived by differentiating the estimated joint angles, achieved an RMSE below 0.6530 rd/s, exceeding 0.9534, and above 0.9552. Additionally, joint power, computed as the dot product of predicted joint moments and angular velocities, resulted in RMSE below 0.3823W/kg, above 0.9771, and above 0.8925. These results demonstrate the effectiveness of the proposed network in continuously estimating lower limb kinematics and kinetics, contributing to advancements in assist-as-needed exoskeleton control strategies.

IEEE Journal of Biomedical and Health InformaticsVol. PP
Chinese Academy of Sciences (CN), Shenzhen Institutes of Advanced Technology (CN)
National Natural Science Foundation of China, China Postdoctoral Science Foundation, Basic and Applied Basic Research Foundation of Guangdong Province
Affordable and clean energy
Openalex Percentile: Top 4%
Muscle activation and electromyography studies
6.07
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.