A Data Analytic Approach for Assessing XLPE Cable Insulation Condition via Resistance Measurements

The insulation resistance (IR) test has been widely conducted by electricity companies to assess cable insulation health status due to its ease of applicability; however, there exist cases in which medium-voltage (MV) power cables pass the IR test but fail in service after reenergization. So far, historical IR data obtained via measurements have been recorded but have never been systematically studied to improve the accuracy of detecting unhealthy cables. This article proposes a data analytic approach using historical IR data to identify patterns for distinguishing between healthy and unhealthy cables and assess the cable insulation condition. The proposed approach first leverages a two-parameter Weibull analysis to link the failure probability of the cables to their ages. Such analysis sheds light on the classification of the cables with respect to their age and material. Next, a diminishing method (DM) is used to set the critical IR values and provide maximum detection of the unhealthy cables with minimum misclassification of the healthy cables as unhealthy. Finally, a self-organizing-map-based support vector machine (SOM-SVM) is used to classify the cables as healthy or unhealthy. The hybrid DM-SOM-SVM approach is applied to the historical IR data of 22 kV and 6.6 kV cross-linked polyethylene (XLPE) cables. Compared to current industrial IR criteria for insulation condition diagnosis, the proposed approach allows the detection of 18.5 and 1.8 times more unhealthy 22 kV and 6.6 kV XLPE distribution cables, respectively.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3555713
Citations
2
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
1.04

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Data Analytic Approach for Assessing XLPE Cable Insulation Condition via Resistance Measurements

Wen Kwang Chern, C. T. Wee, Hoay Beng Gooi, Abdulkadir C. Yücel et al.
2 citations
IEEE Transactions on Instrumentation and Measurement
High voltage insulation and dielectric phenomena
1.04
article

A Data Analytic Approach for Assessing XLPE Cable Insulation Condition via Resistance Measurements

Wen Kwang Chern, C. T. Wee, Hoay Beng Gooi, Abdulkadir C. Yücel, Changyou Suo, Amer M. Y. M. Ghias, Xi Wang, Huajie Yi
article en
2 citations

Abstract

The insulation resistance (IR) test has been widely conducted by electricity companies to assess cable insulation health status due to its ease of applicability; however, there exist cases in which medium-voltage (MV) power cables pass the IR test but fail in service after reenergization. So far, historical IR data obtained via measurements have been recorded but have never been systematically studied to improve the accuracy of detecting unhealthy cables. This article proposes a data analytic approach using historical IR data to identify patterns for distinguishing between healthy and unhealthy cables and assess the cable insulation condition. The proposed approach first leverages a two-parameter Weibull analysis to link the failure probability of the cables to their ages. Such analysis sheds light on the classification of the cables with respect to their age and material. Next, a diminishing method (DM) is used to set the critical IR values and provide maximum detection of the unhealthy cables with minimum misclassification of the healthy cables as unhealthy. Finally, a self-organizing-map-based support vector machine (SOM-SVM) is used to classify the cables as healthy or unhealthy. The hybrid DM-SOM-SVM approach is applied to the historical IR data of 22 kV and 6.6 kV cross-linked polyethylene (XLPE) cables. Compared to current industrial IR criteria for insulation condition diagnosis, the proposed approach allows the detection of 18.5 and 1.8 times more unhealthy 22 kV and 6.6 kV XLPE distribution cables, respectively.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Nanyang Technological University (SG), Singapore Polytechnic (SG), University of Southampton (GB)
Nanyang Technological University
Affordable and clean energy
Openalex Percentile: Top 27%
High voltage insulation and dielectric phenomena
1.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.