Enhanced detection of envelope-following responses for objective fitting of cochlear-implant users

<i>Objective</i>. Electrically evoked auditory steady-state responses (EASSRs) are potential neural responses for objectively determining stimulation parameters of cochlear implants (CIs). Unfortunately, they are difficult to detect in electroencephalography (EEG) recordings due to the electrical stimulation artifacts of the CI. This study investigates a novel stimulation paradigm hypothesized to improve artifact removal efficacy via system identification (SI), and therefore to improve response detection and clinical applicability.<i>Approach</i>. An amplitude-modulated (AM) CI stimulation pulse train with a step-wise increase in modulation frequency is created (referred to as SWEEP stimulation). Another stimulation is created by randomly shuffling modulation frequencies of the SWEEP stimulation (referred to as Shuffled-SWEEP stimulation). AM pulse trains with fixed modulation frequency (referred to as conventional AM stimulation), which elicit EASSRs, are also created for comparison. EEG data is collected from four CI users. A supra-threshold stimulation condition is used to investigate whether the SWEEP and Shuffled-SWEEP stimulation can elicit envelope-following responses (EFRs). A sub-threshold stimulation condition allows the collection of artifact-only EEG data, which is used to compare the SI accuracy on recordings from the SWEEP and the conventional AM stimulation.<i>Main results</i>. In all CI users, neural responses, following the SWEEP, Shuffled-SWEEP, and conventional AM stimulation are detected after artifact removal with SI. The validation with artifact-only EEG data shows higher<i>F</i>1 scores when comparing recordings with SWEEP stimulation (<i>F</i>1 = 0.9) to recordings with conventional AM stimulation (<i>F</i>1 = 0.82).<i>Significance</i>. Being able to accurately identify the response within one EEG recording enables the development of effective, online, objective fitting protocols. The increased neural response detection sensitivity with SWEEP stimulation reduces clinical recording time on average by a factor of 2.07. Detecting EFRs following complex stimulation paradigms offers a potential advancement in the systematic assessment of the temporal envelope processing in CI users.

Authors

Institutions

Publication Details

Journal
Journal of Neural Engineering
Published
2025-03-28
DOI
https://doi.org/10.1088/1741-2552/adc6be
Primary Topic
Hearing Loss and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhanced detection of envelope-following responses for objective fitting of cochlear-implant users

Robin Gransier, Marc Moonen, Jan Wouters, J. Schott
Journal of Neural Engineering
Hearing Loss and Rehabilitation
article

Enhanced detection of envelope-following responses for objective fitting of cochlear-implant users

Robin Gransier, Marc Moonen, Jan Wouters, J. Schott
article en

Abstract

<i>Objective</i>. Electrically evoked auditory steady-state responses (EASSRs) are potential neural responses for objectively determining stimulation parameters of cochlear implants (CIs). Unfortunately, they are difficult to detect in electroencephalography (EEG) recordings due to the electrical stimulation artifacts of the CI. This study investigates a novel stimulation paradigm hypothesized to improve artifact removal efficacy via system identification (SI), and therefore to improve response detection and clinical applicability.<i>Approach</i>. An amplitude-modulated (AM) CI stimulation pulse train with a step-wise increase in modulation frequency is created (referred to as SWEEP stimulation). Another stimulation is created by randomly shuffling modulation frequencies of the SWEEP stimulation (referred to as Shuffled-SWEEP stimulation). AM pulse trains with fixed modulation frequency (referred to as conventional AM stimulation), which elicit EASSRs, are also created for comparison. EEG data is collected from four CI users. A supra-threshold stimulation condition is used to investigate whether the SWEEP and Shuffled-SWEEP stimulation can elicit envelope-following responses (EFRs). A sub-threshold stimulation condition allows the collection of artifact-only EEG data, which is used to compare the SI accuracy on recordings from the SWEEP and the conventional AM stimulation.<i>Main results</i>. In all CI users, neural responses, following the SWEEP, Shuffled-SWEEP, and conventional AM stimulation are detected after artifact removal with SI. The validation with artifact-only EEG data shows higher<i>F</i>1 scores when comparing recordings with SWEEP stimulation (<i>F</i>1 = 0.9) to recordings with conventional AM stimulation (<i>F</i>1 = 0.82).<i>Significance</i>. Being able to accurately identify the response within one EEG recording enables the development of effective, online, objective fitting protocols. The increased neural response detection sensitivity with SWEEP stimulation reduces clinical recording time on average by a factor of 2.07. Detecting EFRs following complex stimulation paradigms offers a potential advancement in the systematic assessment of the temporal envelope processing in CI users.

Journal of Neural EngineeringVol. 22(2)
KU Leuven (BE)
Agentschap Innoveren en Ondernemen
Openalex Percentile: Top 94%
Hearing Loss and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.