A Noncontact Operating System Using Motion Sensors for Image Display to Avoid Communication Errors in Gastrointestinal Fluoroscopy

In endoscopic retrograde cholangiopancreatography, an endoscope is used to insert a catheter into a small area to enable examination and confirm previously obtained images. The endoscopist wears clean gloves, necessitating assistance to operate the image-display system. However, communication errors can hinder the selection of appropriate images from the extensive stored data, potentially prolonging the examination. This study evaluates a noncontact operating system using motion sensors for image display, allowing endoscopists to manage image operations independently during gastrointestinal fluoroscopy. Sixteen operators participated, utilizing both the noncontact operation system and the conventional method. The average image-display operation times for the two methods were compared. The mean image-display completion time was 15.8±3.9 s with the noncontact system and 19.9±9.1 s with the assisted conventional method. The developed system enabled endoscopists to independently operate the image-display system, improving efficiency.

Authors

Institutions

Publication Details

Journal
The Japanese Journal of Ergonomics
Published
2025-02-15
DOI
https://doi.org/10.5100/jje.61.51
Primary Topic
Surgical Simulation and Training
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Noncontact Operating System Using Motion Sensors for Image Display to Avoid Communication Errors in Gastrointestinal Fluoroscopy

Masashi Okamoto, Yohan Kondo, Hiromitsu Daisaki, Toshihiro Ogura et al.
The Japanese Journal of Ergonomics
Surgical Simulation and Training
article

A Noncontact Operating System Using Motion Sensors for Image Display to Avoid Communication Errors in Gastrointestinal Fluoroscopy

Masashi Okamoto, Yohan Kondo, Hiromitsu Daisaki, Toshihiro Ogura, Mitsuru Sato, Zen HAYAMA, Chihiro TSUCHIDA
article en

Abstract

In endoscopic retrograde cholangiopancreatography, an endoscope is used to insert a catheter into a small area to enable examination and confirm previously obtained images. The endoscopist wears clean gloves, necessitating assistance to operate the image-display system. However, communication errors can hinder the selection of appropriate images from the extensive stored data, potentially prolonging the examination. This study evaluates a noncontact operating system using motion sensors for image display, allowing endoscopists to manage image operations independently during gastrointestinal fluoroscopy. Sixteen operators participated, utilizing both the noncontact operation system and the conventional method. The average image-display operation times for the two methods were compared. The mean image-display completion time was 15.8±3.9 s with the noncontact system and 19.9±9.1 s with the assisted conventional method. The developed system enabled endoscopists to independently operate the image-display system, improving efficiency.

The Japanese Journal of ErgonomicsVol. 61(1)
Niigata University (JP), Gunma Prefectural College of Health Sciences (JP)
Openalex Percentile: Top 90%
Surgical Simulation and Training
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.