Single-Centre Experience with the Balloon-Expandable Myval Transcatheter Aortic Valve System with the First 200 Patients: 30-Day and 1-Year Follow-Up

<b>Aims</b>: The aim of this paper is to report 30-day and 1-year outcome data regarding the first 200 patients who underwent the TAVR procedure using the Myval THV system at our single centre. <b>Methods</b>: From November 2019 to October 2022, 200 consecutive patients underwent TAVR procedure. Outcomes were analysed according to the VARC-2 definitions, and device performance was assessed via transthoracic echocardiography. Data collection was approved by the local Ethical Committee. <b>Results</b>: The mean age of the cohort was 75.3 ± 6.9 years, and 122 (61%) participants were male. The mean EuroSCORE II and STS was 5.4 ± 5.4 and 5.8 ± 3.8, respectively. The proportion of patients with a bicuspid aortic valve was 18%. The transfemoral access approach was the most common (surgical vs. percutaneous: 1% vs. 98%), and in two patients, surgical subclavian access was used. VARC-2 outcomes were as follows: 99% device success, 2% STROKE, 5% and 4.5% major and minor vascular complications, respectively, and a 29.5% rate of new permanent pacemaker implantation. At discharge, the incidence of aortic regurgitation grade II or above was 5.5% without relevant PVL (grade II or above 0.5%). In-hospital mortality was only 1%. At 1 year, the all-cause mortality rate was 8.5% (cardiac origin in three cases), and two patients had valve-related dysfunction requiring surgical aortic replacement. <b>Conclusions</b>: Our results showed excellent 30-day and 1-year outcomes regarding patient survival, technical success, and valve-related adverse events using the Myval transcatheter heart valve system. The limitations of our study comprise a single-centre design with retrospective data collection.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-03-28
DOI
https://doi.org/10.3390/jcm14072323
Citations
1
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
1.39

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Single-Centre Experience with the Balloon-Expandable Myval Transcatheter Aortic Valve System with the First 200 Patients: 30-Day and 1-Year Follow-Up

István Szokodi, Ilona Goják, Andrea Bertalan, Bálint Kittka et al.
1 citations
Journal of Clinical Medicine
Cardiac Valve Diseases and Treatments
1.39
article

Single-Centre Experience with the Balloon-Expandable Myval Transcatheter Aortic Valve System with the First 200 Patients: 30-Day and 1-Year Follow-Up

István Szokodi, Ilona Goják, Andrea Bertalan, Bálint Kittka, Gábor Kasza, Mihály Simon, Kristóf Schönfeld, Rudolf Kiss, Balázs Magyari, László Szapáry, Iván Gábor Horváth, Edit Várady
article en
1 citations

Abstract

<b>Aims</b>: The aim of this paper is to report 30-day and 1-year outcome data regarding the first 200 patients who underwent the TAVR procedure using the Myval THV system at our single centre. <b>Methods</b>: From November 2019 to October 2022, 200 consecutive patients underwent TAVR procedure. Outcomes were analysed according to the VARC-2 definitions, and device performance was assessed via transthoracic echocardiography. Data collection was approved by the local Ethical Committee. <b>Results</b>: The mean age of the cohort was 75.3 ± 6.9 years, and 122 (61%) participants were male. The mean EuroSCORE II and STS was 5.4 ± 5.4 and 5.8 ± 3.8, respectively. The proportion of patients with a bicuspid aortic valve was 18%. The transfemoral access approach was the most common (surgical vs. percutaneous: 1% vs. 98%), and in two patients, surgical subclavian access was used. VARC-2 outcomes were as follows: 99% device success, 2% STROKE, 5% and 4.5% major and minor vascular complications, respectively, and a 29.5% rate of new permanent pacemaker implantation. At discharge, the incidence of aortic regurgitation grade II or above was 5.5% without relevant PVL (grade II or above 0.5%). In-hospital mortality was only 1%. At 1 year, the all-cause mortality rate was 8.5% (cardiac origin in three cases), and two patients had valve-related dysfunction requiring surgical aortic replacement. <b>Conclusions</b>: Our results showed excellent 30-day and 1-year outcomes regarding patient survival, technical success, and valve-related adverse events using the Myval transcatheter heart valve system. The limitations of our study comprise a single-centre design with retrospective data collection.

Journal of Clinical MedicineVol. 14(7)
University of Pecs (HU)
Nemzeti Kutatási Fejlesztési és Innovációs Hivatal
Good health and well-being
Openalex Percentile: Top 21%
Cardiac Valve Diseases and Treatments
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.