LOSS OF LIGHT INTENSITY OF DENTAL PHOTOPOLYMERIZERS IN GLASS IONOMER CEMENTS

Relevance. For hybrid dualand tri-cure glass ionomer cements, it is necessary to determine certain irradiation conditions. Objective. To determine the loss of light intensity of photopolymerizers with different characteristics in glass ionomer cements. Materials and Methods. The loss of light intensity from a halogen photopolymerizer and two LED photopolymerizers was studied in 60 samples of dual-cure hybrid glass ionomer cement in shades A1 and A4 (Groups 1 and 2) and 60 samples of tri-cure glass ionomer cement in the same shades (Groups 3 and 4). Ten samples of 4 mm thickness from each group were irradiated for curing, and the loss of light intensity was measured. The samples were then polished to 3 mm and 2 mm thicknesses, and the losses were reevaluated. Results. The greatest losses in light intensity were observed with the halogen photopolymerizer, which had the lowest initial output (812.5±9.7 mW/cm²). The maximum light intensity loss for this photopolymerizer was recorded in 4 mm-thick samples of both cements in the darkest shade, A4, amounting to 94.7±2.2% and 92.1±2.4%, respectively. Higher initial light intensity from LED photopolymerizers resulted in systematically lower losses. The minimal light intensity loss was recorded with the LED photopolymerizer with the highest initial output (1434.8±7.9 mW/cm²) in 2 mm-thick samples of both cements in the lightest shade, A1, at 53.9±1.9% and 51.3±1.5%. The most significant reduction in light intensity was observed between 3 mm and 4 mm sample thicknesses compared to 2 mm and 3 mm, regardless of material, shade, or initial light intensity. Conclusions. When using hybrid dualand tri-cure glass ionomer cements, it is necessary to consider not only the layer thickness but also the material shades and the initial light intensity parameters.

Authors

Institutions

Publication Details

Journal
Ukrainian Dental Almanac
Published
2025-03-28
DOI
https://doi.org/10.31718/2409-0255.1.2025.04
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

LOSS OF LIGHT INTENSITY OF DENTAL PHOTOPOLYMERIZERS IN GLASS IONOMER CEMENTS

О. А. Удод, O.O. Yefimova
2 links
Ukrainian Dental Almanac
Dental materials and restorations
article

LOSS OF LIGHT INTENSITY OF DENTAL PHOTOPOLYMERIZERS IN GLASS IONOMER CEMENTS

О. А. Удод, O.O. Yefimova
article en

Abstract

Relevance. For hybrid dualand tri-cure glass ionomer cements, it is necessary to determine certain irradiation conditions. Objective. To determine the loss of light intensity of photopolymerizers with different characteristics in glass ionomer cements. Materials and Methods. The loss of light intensity from a halogen photopolymerizer and two LED photopolymerizers was studied in 60 samples of dual-cure hybrid glass ionomer cement in shades A1 and A4 (Groups 1 and 2) and 60 samples of tri-cure glass ionomer cement in the same shades (Groups 3 and 4). Ten samples of 4 mm thickness from each group were irradiated for curing, and the loss of light intensity was measured. The samples were then polished to 3 mm and 2 mm thicknesses, and the losses were reevaluated. Results. The greatest losses in light intensity were observed with the halogen photopolymerizer, which had the lowest initial output (812.5±9.7 mW/cm²). The maximum light intensity loss for this photopolymerizer was recorded in 4 mm-thick samples of both cements in the darkest shade, A4, amounting to 94.7±2.2% and 92.1±2.4%, respectively. Higher initial light intensity from LED photopolymerizers resulted in systematically lower losses. The minimal light intensity loss was recorded with the LED photopolymerizer with the highest initial output (1434.8±7.9 mW/cm²) in 2 mm-thick samples of both cements in the lightest shade, A1, at 53.9±1.9% and 51.3±1.5%. The most significant reduction in light intensity was observed between 3 mm and 4 mm sample thicknesses compared to 2 mm and 3 mm, regardless of material, shade, or initial light intensity. Conclusions. When using hybrid dualand tri-cure glass ionomer cements, it is necessary to consider not only the layer thickness but also the material shades and the initial light intensity parameters.

Ukrainian Dental Almanac(1)
Donetsk National Medical University (UA)
Openalex Percentile: Top 94%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.