Morphological Studies on the Wear and Corrosion of 316L Stainless Steel Dynamic Compression Plates

316L stainless steel dynamic compression plates (DCP) extracted from four patients with varying periods of implantation as well as an unused 316L stainless steel DCP were studied with the aid of the Scanning electron microscope (SEM). Image processing and computer vision such as binarization, filtering, edge detection and contour finding were used to extract details from the SEM micrographs with emphasis on the possible impacts of duration of implantation and wear on the microstructure of the metallic material. Results obtained show that there were considerable impacts on the microstructure of the stainless steel implants over time, with higher impacts observed for implants with longer period of implantation.

Authors

Institutions

Publication Details

Journal
Journal of Long-Term Effects of Medical Implants
Published
2025-03-28
DOI
https://doi.org/10.1615/jlongtermeffmedimplants.2025052679
Primary Topic
Mechanical Failure Analysis and Simulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Morphological Studies on the Wear and Corrosion of 316L Stainless Steel Dynamic Compression Plates

C. K. Anyiam, O. A. Okeke, Ruth Onwuegbuchulam
1 links
Journal of Long-Term Effects of Medical Implants
Mechanical Failure Analysis and Simulation
article

Morphological Studies on the Wear and Corrosion of 316L Stainless Steel Dynamic Compression Plates

C. K. Anyiam, O. A. Okeke, Ruth Onwuegbuchulam
article en

Abstract

316L stainless steel dynamic compression plates (DCP) extracted from four patients with varying periods of implantation as well as an unused 316L stainless steel DCP were studied with the aid of the Scanning electron microscope (SEM). Image processing and computer vision such as binarization, filtering, edge detection and contour finding were used to extract details from the SEM micrographs with emphasis on the possible impacts of duration of implantation and wear on the microstructure of the metallic material. Results obtained show that there were considerable impacts on the microstructure of the stainless steel implants over time, with higher impacts observed for implants with longer period of implantation.

Journal of Long-Term Effects of Medical ImplantsVol. 36(1)
Federal University of Technology Owerri (NG)
Openalex Percentile: Top 94%
Mechanical Failure Analysis and Simulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies