Optimization of heating curves for heat pumps in operation: Outdoor temperature ranges for energy-efficient heating curve shifts

In the light of global sustainability efforts, heat pumps offer environmental benefits, but their complexity and potential misconfigurations often lead to homeowner dissatisfaction due to inaccurate heating and lower-than-expected efficiency. Among the most important and complex settings is the heating curve and yet there are no easy-to-use methods to optimize it after its initial set-up. This study aims to develop ready-to-use guidelines for optimizing the heating curve with energy-efficient adjustments that improve room comfort and prevent suboptimal user changes, all without requiring additional sensors like room thermostats. Based on interpretable linear models, estimated on 3995 air-to-water heat pumps, located in Central Europe, we select the least energy-intensive heating curve shift for each outdoor temperature, needed to meet room thermal comfort. We find that the standard parallel shift of the heating curve is only the optimal approach when the average outdoor temperature is between 2 ∘ C and 5 ∘ C. Outside this range, the heating curve should be moved at its starting or the endpoint. Simulation shows that by translating user input to the room controller with our proposed changes, 84.42 % of the heating curves can be improved, reducing the share of misconfigured heating curves from 24.01 % to 7.08 %. This leads to an average reduction in yearly energy consumption of 4.02 % and an increase in the seasonal coefficient of performance by 2.59 % on average. By introducing ready-to-use heating curve improvement guidelines, we aim to increase efficiency and confidence in heat pump technology, ensuring its adoption to meet carbon emission targets. • Method to derive heating curve optimization guidelines, implementable by residents. • Study is based on observational data from 3995 air-to-water heat pumps, located in average climate. • Standard parallel shift of the heating curve is preferable only for T outdoor ∈ [2,5] ∘ C. • 84.42 % of the heating curves can be improved, reducing yearly energy consumption by 4.02 % on average. • Significantly reduced number of misconfigured heating curves from 24.01 % to 7.08 %.

Authors

Institutions

Publication Details

Journal
Applied Energy
Published
2025-03-28
DOI
https://doi.org/10.1016/j.apenergy.2025.125725
Citations
5
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
5.03
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of heating curves for heat pumps in operation: Outdoor temperature ranges for energy-efficient heating curve shifts

Konstantin Hopf, Tobias Brudermueller, Felix Wortmann, Ugne Potthoff
5 citations
Applied Energy
Building Energy and Comfort Optimization
5.03
article

Optimization of heating curves for heat pumps in operation: Outdoor temperature ranges for energy-efficient heating curve shifts

Konstantin Hopf, Tobias Brudermueller, Felix Wortmann, Ugne Potthoff
article en
5 citations

Abstract

In the light of global sustainability efforts, heat pumps offer environmental benefits, but their complexity and potential misconfigurations often lead to homeowner dissatisfaction due to inaccurate heating and lower-than-expected efficiency. Among the most important and complex settings is the heating curve and yet there are no easy-to-use methods to optimize it after its initial set-up. This study aims to develop ready-to-use guidelines for optimizing the heating curve with energy-efficient adjustments that improve room comfort and prevent suboptimal user changes, all without requiring additional sensors like room thermostats. Based on interpretable linear models, estimated on 3995 air-to-water heat pumps, located in Central Europe, we select the least energy-intensive heating curve shift for each outdoor temperature, needed to meet room thermal comfort. We find that the standard parallel shift of the heating curve is only the optimal approach when the average outdoor temperature is between 2 ∘ C and 5 ∘ C. Outside this range, the heating curve should be moved at its starting or the endpoint. Simulation shows that by translating user input to the room controller with our proposed changes, 84.42 % of the heating curves can be improved, reducing the share of misconfigured heating curves from 24.01 % to 7.08 %. This leads to an average reduction in yearly energy consumption of 4.02 % and an increase in the seasonal coefficient of performance by 2.59 % on average. By introducing ready-to-use heating curve improvement guidelines, we aim to increase efficiency and confidence in heat pump technology, ensuring its adoption to meet carbon emission targets. • Method to derive heating curve optimization guidelines, implementable by residents. • Study is based on observational data from 3995 air-to-water heat pumps, located in average climate. • Standard parallel shift of the heating curve is preferable only for T outdoor ∈ [2,5] ∘ C. • 84.42 % of the heating curves can be improved, reducing yearly energy consumption by 4.02 % on average. • Significantly reduced number of misconfigured heating curves from 24.01 % to 7.08 %.

Applied EnergyVol. 389
University of St.Gallen (CH), ETH Zurich (CH), University of Bamberg (DE)
Affordable and clean energy
Openalex Percentile: Top 5%
Building Energy and Comfort Optimization
5.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.