Vascular Perfusion Variability in Diabetic Retinopathy: A Sequential Interscan Optical Coherence Tomography Angiography Assessment

<b>Background/Objectives</b>: The aim of this study was to quantify the interscan variability of vascular perfusion in patients with diabetic retinopathy (DR) using sequential optical coherence tomography angiography (OCT-A) scans. <b>Methods</b>: Patients with low-grade DR (DRSS score 20) underwent five sequential OCT-A imaging sessions. Vessel perfusion density (VPD) values of the superficial capillary plexus (SCP), intermediate capillary plexus (ICP), deep capillary plexus (DCP), and choriocapillaris (CC) were computed using ImageJ Version 1.54 software via a binarization process. The binarized images were analyzed to compute VPD using vessel density plugins. Inter-session variability was assessed using the coefficient of variation (CV) and intraclass correlation coefficient (ICC). The results were compared with an age-matched group of healthy controls. <b>Results</b>: A total of 16 eyes from 16 patients with DR (6 females, 37.5%) and 16 eyes from healthy controls (6 females, 37.5%) were included. Mean VPD values for SCP, ICP, DCP, and CC in patients with DR were 23.64, 13.64, 15.31, and 36.57, respectively. Corresponding values for the healthy subjects were 37.65, 23.32, 22.05, and 49.00, respectively. No significant differences were found in VPD across consecutive scanning sessions (<i>p</i> > 0.05) in either group. However, significant differences in VPD were observed between patients who were healthy and patients with diabetes. <b>Conclusions</b>: Sequential OCT-A imaging demonstrated no significant inter-session variability in both healthy subjects and subjects with diabetes. The Spectralis OCT-A system showed high reliability for imaging both healthy and diseased conditions.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-03-28
DOI
https://doi.org/10.3390/jcm14072312
Citations
1
Primary Topic
Retinal Imaging and Analysis
Type
article
Field-Weighted Citation Impact
1.36
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Vascular Perfusion Variability in Diabetic Retinopathy: A Sequential Interscan Optical Coherence Tomography Angiography Assessment

Lorenzo Mangoni, Rosa Dolz‐Marco, Cesare Mariotti, Alessio Muzi et al.
1 citations
Journal of Clinical Medicine
Retinal Imaging and Analysis
1.36
article

Vascular Perfusion Variability in Diabetic Retinopathy: A Sequential Interscan Optical Coherence Tomography Angiography Assessment

Lorenzo Mangoni, Rosa Dolz‐Marco, Cesare Mariotti, Alessio Muzi, Daniela Fruttini, Ramkailash Gujar, Giulia Gregori, Jay Kumar Chhablani, Marco Lupidi, Mario Chiapponi, Veronica Mogetta
article en
1 citations

Abstract

<b>Background/Objectives</b>: The aim of this study was to quantify the interscan variability of vascular perfusion in patients with diabetic retinopathy (DR) using sequential optical coherence tomography angiography (OCT-A) scans. <b>Methods</b>: Patients with low-grade DR (DRSS score 20) underwent five sequential OCT-A imaging sessions. Vessel perfusion density (VPD) values of the superficial capillary plexus (SCP), intermediate capillary plexus (ICP), deep capillary plexus (DCP), and choriocapillaris (CC) were computed using ImageJ Version 1.54 software via a binarization process. The binarized images were analyzed to compute VPD using vessel density plugins. Inter-session variability was assessed using the coefficient of variation (CV) and intraclass correlation coefficient (ICC). The results were compared with an age-matched group of healthy controls. <b>Results</b>: A total of 16 eyes from 16 patients with DR (6 females, 37.5%) and 16 eyes from healthy controls (6 females, 37.5%) were included. Mean VPD values for SCP, ICP, DCP, and CC in patients with DR were 23.64, 13.64, 15.31, and 36.57, respectively. Corresponding values for the healthy subjects were 37.65, 23.32, 22.05, and 49.00, respectively. No significant differences were found in VPD across consecutive scanning sessions (<i>p</i> > 0.05) in either group. However, significant differences in VPD were observed between patients who were healthy and patients with diabetes. <b>Conclusions</b>: Sequential OCT-A imaging demonstrated no significant inter-session variability in both healthy subjects and subjects with diabetes. The Spectralis OCT-A system showed high reliability for imaging both healthy and diseased conditions.

Journal of Clinical MedicineVol. 14(7)
Marche Polytechnic University (IT), University of Perugia (IT), Ospedale Humanitas Gradenigo (IT), IVI Valencia Clinic (ES), University of Pittsburgh Medical Center (US), Dr. Shroff’s Charity Eye Hospital (IN)
Openalex Percentile: Top 22%
Retinal Imaging and Analysis
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.