Rotor Location During Atrial Fibrillation: A Framework Based on Data Fusion and Information Quality

Persistent atrial fibrillation (AF), a prevalent cardiac arrhythmia, is primarily sustained by rotor-type reentries, with their localization crucial for successful ablation treatment. Fractionated atrial electrogram (EGM) signals have been associated with the tips of the rotors and are thus considered as ablation targets. However, the typical noise problems of physiological signals affect the results of EGM processing tools, and consequently the ablation outcome. This study proposes a data fusion framework based on the Joint Directors of Laboratories model with six levels and information quality (IQ) assessment for locating rotor tips from EGMs simulated in a two-dimensional model of human atrial tissue under AF conditions. Validation tests were conducted using a set of 13 IQ criteria and their corresponding metrics. First, EGMs were contaminated with different types of noise and artifacts (power-line interference, spikes, loss of samples, and loss of resolution) to assess tolerance. The signals were then preprocessed, and five statistical features (sample entropy, approximate entropy, Shannon entropy, mean amplitude, and standard deviation) were extracted to generate rotor location maps using a wavelet fusion technique. Fuzzy inference was applied for situation and risk assessment, followed by IQ mapping using a support vector machine by level. Finally, the IQ criteria were optimized through a particle swarm optimization algorithm. The proposed framework outperformed existing EGM-based rotor detection methods, demonstrating superior functionality and performance compared to existing EGM-based rotor detection methods. It achieved an accuracy of approximately 90%, with improvements of up to 10% through tuning and adjustments based on IQ variables, aligned with higher-level system requirements. The novelty of this approach lies in evaluating the IQ across signal-processing stages and optimizing it through data fusion to enhance rotor tip position estimation. This advancement could help specialists make more informed decisions in EGM acquisition and treatment application.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-03-27
DOI
https://doi.org/10.3390/app15073665
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rotor Location During Atrial Fibrillation: A Framework Based on Data Fusion and Information Quality

Cristian Mejía, Miguel A. Becerra, Catalina Tobón, Diego H. Peluffo-Ordóńez et al.
Applied Sciences
Atrial Fibrillation Management and Outcomes
article

Rotor Location During Atrial Fibrillation: A Framework Based on Data Fusion and Information Quality

Cristian Mejía, Miguel A. Becerra, Catalina Tobón, Diego H. Peluffo-Ordóńez, Juan Ugarte, Johana Elizabeth Vela
article en

Abstract

Persistent atrial fibrillation (AF), a prevalent cardiac arrhythmia, is primarily sustained by rotor-type reentries, with their localization crucial for successful ablation treatment. Fractionated atrial electrogram (EGM) signals have been associated with the tips of the rotors and are thus considered as ablation targets. However, the typical noise problems of physiological signals affect the results of EGM processing tools, and consequently the ablation outcome. This study proposes a data fusion framework based on the Joint Directors of Laboratories model with six levels and information quality (IQ) assessment for locating rotor tips from EGMs simulated in a two-dimensional model of human atrial tissue under AF conditions. Validation tests were conducted using a set of 13 IQ criteria and their corresponding metrics. First, EGMs were contaminated with different types of noise and artifacts (power-line interference, spikes, loss of samples, and loss of resolution) to assess tolerance. The signals were then preprocessed, and five statistical features (sample entropy, approximate entropy, Shannon entropy, mean amplitude, and standard deviation) were extracted to generate rotor location maps using a wavelet fusion technique. Fuzzy inference was applied for situation and risk assessment, followed by IQ mapping using a support vector machine by level. Finally, the IQ criteria were optimized through a particle swarm optimization algorithm. The proposed framework outperformed existing EGM-based rotor detection methods, demonstrating superior functionality and performance compared to existing EGM-based rotor detection methods. It achieved an accuracy of approximately 90%, with improvements of up to 10% through tuning and adjustments based on IQ variables, aligned with higher-level system requirements. The novelty of this approach lies in evaluating the IQ across signal-processing stages and optimizing it through data fusion to enhance rotor tip position estimation. This advancement could help specialists make more informed decisions in EGM acquisition and treatment application.

Applied SciencesVol. 15(7)
Institución Universitaria Pascual Bravo (CO), Université Mohammed VI Polytechnique (MA), Universidad de Medellín (CO), Instituto Tecnológico Metropolitano (CO), Universidad de San Buenaventura, Bogota (CO)
Openalex Percentile: Top 91%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.