Rapid Path Planning Algorithm for Percutaneous Rigid Needle Biopsy Based on Optical Illumination Principles

Optimal needle trajectory selection is critical in biopsy procedures to minimize tissue damage and ensure diagnostic accuracy. Timely trajectory planning is essential, as it relies on preoperative CT imaging. Prolonged processing times increase the risk of patient movement, rendering the planned path invalid. Traditional methods relying on clinician expertise or slow algorithms struggle with complex anatomical modeling for structures such as blood vessels. We introduce a novel method that reframes trajectory planning as an optimal puncture site identification problem by leveraging optical principles and computer rendering. A 3D model of key anatomical structures is reconstructed from CT images and segmented using SegResNet (average Dice similarity coefficient of 0.9122). A virtual light source positioned at the target illuminates the space, assigning distinct absorption coefficients to tissues based on needle permissibility and risk. Diffuse reflection simulates needle angle, and accumulated absorption represents depth, capturing puncture constraints. This simulation generates a grayscale map on the skin surface, highlighting candidate puncture sites. Furthermore, we employ a random forest-based method to model clinician preferences. This model analyzes an RGB image derived from the grayscale distribution to automatically select the optimal path and determine the needle entry point. The experimental evaluation demonstrates an average computation time of just 1.905 s per sample, which is significantly faster than traditional methods that require seconds to minutes. Moreover, clinical assessment by a thoracic surgeon found that 78% of the recommended paths met clinical standards, with 0% deemed unsatisfactory. These findings suggest that our method provides a rapid, intuitive, and reliable decision-support tool, improving biopsy safety and efficiency.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-03-28
DOI
https://doi.org/10.3390/s25072137
Citations
3
Primary Topic
AI in cancer detection
Type
article
Field-Weighted Citation Impact
7.44
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid Path Planning Algorithm for Percutaneous Rigid Needle Biopsy Based on Optical Illumination Principles

Kai Xu, Kang Shuai, Dongxia Zhang, Juan Ren et al.
3 citations
Sensors
AI in cancer detection
7.44
article

Rapid Path Planning Algorithm for Percutaneous Rigid Needle Biopsy Based on Optical Illumination Principles

Kai Xu, Kang Shuai, Dongxia Zhang, Juan Ren, Bing Niu, Jian Liu
article en
3 citations

Abstract

Optimal needle trajectory selection is critical in biopsy procedures to minimize tissue damage and ensure diagnostic accuracy. Timely trajectory planning is essential, as it relies on preoperative CT imaging. Prolonged processing times increase the risk of patient movement, rendering the planned path invalid. Traditional methods relying on clinician expertise or slow algorithms struggle with complex anatomical modeling for structures such as blood vessels. We introduce a novel method that reframes trajectory planning as an optimal puncture site identification problem by leveraging optical principles and computer rendering. A 3D model of key anatomical structures is reconstructed from CT images and segmented using SegResNet (average Dice similarity coefficient of 0.9122). A virtual light source positioned at the target illuminates the space, assigning distinct absorption coefficients to tissues based on needle permissibility and risk. Diffuse reflection simulates needle angle, and accumulated absorption represents depth, capturing puncture constraints. This simulation generates a grayscale map on the skin surface, highlighting candidate puncture sites. Furthermore, we employ a random forest-based method to model clinician preferences. This model analyzes an RGB image derived from the grayscale distribution to automatically select the optimal path and determine the needle entry point. The experimental evaluation demonstrates an average computation time of just 1.905 s per sample, which is significantly faster than traditional methods that require seconds to minutes. Moreover, clinical assessment by a thoracic surgeon found that 78% of the recommended paths met clinical standards, with 0% deemed unsatisfactory. These findings suggest that our method provides a rapid, intuitive, and reliable decision-support tool, improving biopsy safety and efficiency.

SensorsVol. 25(7)
Shanghai Jiao Tong University (CN)
Openalex Percentile: Top 4%
AI in cancer detection
7.44
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.