Outcomes of localized corneal collagen crosslinking with a conventional device in progressive keratoconus
In this series, cone-centered L-CXL, using a conventional CXL device resulted in significant stabilization and even improvements in BDVA and Kmax in almost half of the eyes, without significant adverse events. Addressing the CXL application onto the affected area results in beneficial results.
Authors
- Nir Gomel (ORCID: https://orcid.org/0000-0002-4771-1374)
- Irina S. Barequet
- Yoav Berger
- Rachel Shemesh (ORCID: https://orcid.org/0000-0001-9572-4623)
- Ofri Vorobichik Berar (ORCID: https://orcid.org/0000-0002-8503-8862)
Institutions
- Tel Aviv University (IL)
- Tel Aviv Sourasky Medical Center (IL)
- Sheba Medical Center (IL)
Publication Details
- Journal
- Graefe s Archive for Clinical and Experimental Ophthalmology
- Published
- 2025-03-27
- DOI
- https://doi.org/10.1007/s00417-025-06803-y
- Primary Topic
- Corneal surgery and disorders
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Tel Aviv University