Adverse events and ICU readmission rates after floor transfer for paediatric patients on ventricular assist device support

Paediatric ventricular assist device patients, including those with single ventricle anatomy, are increasingly managed outside of the ICU. We used retrospective chart review of our single centre experience to quantify adverse event rates and ICU readmissions for 22 complex paediatric patients on ventricular assist device support (15 two ventricles, 7 single ventricle) after floor transfer. The median age was 1.65 years. The majority utilised the Berlin EXCOR (17, 77.3%). There were 9 ICU readmissions with median length of stay of 2 days. Adverse events were noted in 9 patients (41%), with infection being most common (1.8 events per patient year). There were no deaths. Single ventricle patients had a higher proportion of ICU readmission and adverse events. ICU readmission rates were low, and adverse event rates were comparable to published rates suggesting ventricular assist device patients can be safely managed on the floor.

Authors

Institutions

Publication Details

Journal
Cardiology in the Young
Published
2025-03-28
DOI
https://doi.org/10.1017/s1047951125001234
Primary Topic
Childhood Cancer Survivors' Quality of Life
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Adverse events and ICU readmission rates after floor transfer for paediatric patients on ventricular assist device support

Kari A. Phillips, Brandon Kirkland, Lindsay J. May, Geoffrey Hadfield et al.
Cardiology in the Young
Childhood Cancer Survivors' Quality of Life
article

Adverse events and ICU readmission rates after floor transfer for paediatric patients on ventricular assist device support

Kari A. Phillips, Brandon Kirkland, Lindsay J. May, Geoffrey Hadfield, Michelle Ploutz, Caroline Heyrend, Eric R. Griffiths, Michael Profsky, Amanda Brennan
article en

Abstract

Paediatric ventricular assist device patients, including those with single ventricle anatomy, are increasingly managed outside of the ICU. We used retrospective chart review of our single centre experience to quantify adverse event rates and ICU readmissions for 22 complex paediatric patients on ventricular assist device support (15 two ventricles, 7 single ventricle) after floor transfer. The median age was 1.65 years. The majority utilised the Berlin EXCOR (17, 77.3%). There were 9 ICU readmissions with median length of stay of 2 days. Adverse events were noted in 9 patients (41%), with infection being most common (1.8 events per patient year). There were no deaths. Single ventricle patients had a higher proportion of ICU readmission and adverse events. ICU readmission rates were low, and adverse event rates were comparable to published rates suggesting ventricular assist device patients can be safely managed on the floor.

Cardiology in the YoungVol. 35(5)
Primary Children's Hospital (US), University of Utah (US)
Good health and well-being
Openalex Percentile: Top 92%
Childhood Cancer Survivors' Quality of Life
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Adverse events and ICU readmission rates after floor transfer for paediatric patients on ventricular assist device support — Kari A. Phillips, Brandon Kirkland, et al. · Cardiology in the Young (2025) | TGRS Research Map | TGRS