Effects of residual particles and multiply charged particles of a polystyrene latex particle on the particle filtration efficiency of a medical face masks

The objective of this study is to elucidate the impact of residual particles and multiply charged particles of polystyrene latex (PSL) particles on the particle filtration efficiency of a medical face mask. Adhering to the ASTM F2299 test methodology, this investigation employed a PSL particle (Thermo ScientificTM Dri-CalTM) with a diameter of 100 nanometers and a geometric standard deviation of approximately 1.6%. The scanning mobility particle sizer (SMPS) was utilized to ascertain the size distribution of PSL particles both upstream and downstream of the test face mask, thereby determining the particle filtration efficiency of the face mask for residual particles and multiply charged particles at various PSL particle-to-DI water ratios. The PSL particle-to-DI water ratios employed in this study were 10, 20, and 100 drops per 200 mL, respectively. The findings revealed that PSL suspension residual particles with a mobility diameter less than 60 nanometers, as well as multiple charged particles with a mobility diameter exceeding 100 nanometers, introduced complexity to purportedly monodisperse particle aerosols. An increase in PSL suspension concentration resulted in a heightened relevance of the residual peak. At elevated concentrations, PSL multiply charged particles became discernible in the size distribution. Furthermore, it was demonstrated that as the PSL particle-to-DI water ratios increased, the particle filtration efficiency of the test face mask diminished for both single charged particles and multiply charged particles (+2, +3, +4, and +5).

Authors

Institutions

Publication Details

Journal
Engineering and Technology Horizons
Published
2025-03-27
DOI
https://doi.org/10.55003/eth.420103
Primary Topic
Aerosol Filtration and Electrostatic Precipitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of residual particles and multiply charged particles of a polystyrene latex particle on the particle filtration efficiency of a medical face masks

Papol Sardyoung, Panich Intra, Theerachot Lawong, Wisanapat Rattanachan
Engineering and Technology Horizons
Aerosol Filtration and Electrostatic Precipitation
article

Effects of residual particles and multiply charged particles of a polystyrene latex particle on the particle filtration efficiency of a medical face masks

Papol Sardyoung, Panich Intra, Theerachot Lawong, Wisanapat Rattanachan
article en

Abstract

The objective of this study is to elucidate the impact of residual particles and multiply charged particles of polystyrene latex (PSL) particles on the particle filtration efficiency of a medical face mask. Adhering to the ASTM F2299 test methodology, this investigation employed a PSL particle (Thermo ScientificTM Dri-CalTM) with a diameter of 100 nanometers and a geometric standard deviation of approximately 1.6%. The scanning mobility particle sizer (SMPS) was utilized to ascertain the size distribution of PSL particles both upstream and downstream of the test face mask, thereby determining the particle filtration efficiency of the face mask for residual particles and multiply charged particles at various PSL particle-to-DI water ratios. The PSL particle-to-DI water ratios employed in this study were 10, 20, and 100 drops per 200 mL, respectively. The findings revealed that PSL suspension residual particles with a mobility diameter less than 60 nanometers, as well as multiple charged particles with a mobility diameter exceeding 100 nanometers, introduced complexity to purportedly monodisperse particle aerosols. An increase in PSL suspension concentration resulted in a heightened relevance of the residual peak. At elevated concentrations, PSL multiply charged particles became discernible in the size distribution. Furthermore, it was demonstrated that as the PSL particle-to-DI water ratios increased, the particle filtration efficiency of the test face mask diminished for both single charged particles and multiply charged particles (+2, +3, +4, and +5).

Engineering and Technology HorizonsVol. 42(1)
ITRI International (US), Thepsatri Rajabhat University (TH), Chiang Mai University (TH), Rajamangala University of Technology Lanna (TH)
Openalex Percentile: Top 95%
Aerosol Filtration and Electrostatic Precipitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.