THE POTENTIAL ENERGY IMPACT OF THE SUCTION TUBE OF PUMPING FACILITIES ON THE MARK OF PUMP AXIS INSTALLATION AND THE POWER CONSUMPTION OF DRIVE MOTORS

Purpose: to substantiate theoretically the impact of the potential energy of suction tube of pumping facilities on the installation mark of the pump axis and the drive motor power. Materials and methods. The theoretical studies were based on the substantiation of the impact of potential energy in the pump housing on head, on the analysis of dependence of hydraulic resistances coefficients in the suction tube on the installation height of the pump axis relative to the water source surface and on the impact of potential energy in the suction tube on the useful power of drive motors. Results. It has been determined that when designing pumping facilities, the pump axis mark and the drive motor power are affected by the potential energy in the suction tube, ranging from positive to negative value. When analyzing the K90/85 pump characteristics, it was found that there was no significant effect of kinetic energy. The main influencing factor on potential energy is the hydraulic resistance coefficient, which varies during operation due to corrosion of the inner surface of the pipeline. When hydraulic resistance coefficient changes from 0.02 to 0.5, the pump axis installation mark ranges from +1.92 to –31.11 m, which leads to a complete stop of the supply feed. Studying the influence of the pipeline length, it was found that the height of the pump axis installation varies from +3.24 to –3.43 m, which indicates the degree of the pumping station building depth. In the study of impact of potential energy on the drive motor power, a decrease from 23.59 to 17.8 kW with a corresponding increase in the total energy in the suction pipeline from 3.28 to 26.92 m was stated. Conclusions: when operating existing and newly designed pumping stations, it should be borne in mind that there is a constant value of the velocity head in the suction pipeline not exceeding 0.2–0.3 m with appropriate diameter selection and the possibility of increasing the coefficient of hydraulic resistance for the inner surface during operation.

Authors

Publication Details

Journal
Land Reclamation and Hydraulic Engineering
Published
2025-01-01
DOI
https://doi.org/10.31774/2712-9357-2025-15-1-216-231
Primary Topic
Hydraulic and Pneumatic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

THE POTENTIAL ENERGY IMPACT OF THE SUCTION TUBE OF PUMPING FACILITIES ON THE MARK OF PUMP AXIS INSTALLATION AND THE POWER CONSUMPTION OF DRIVE MOTORS

Ruslan Rasulovich Mazanov, D Tsyplenkov, Yulia S. Urzhumova, Irina N. Vinokurova
Land Reclamation and Hydraulic Engineering
Hydraulic and Pneumatic Systems
article

THE POTENTIAL ENERGY IMPACT OF THE SUCTION TUBE OF PUMPING FACILITIES ON THE MARK OF PUMP AXIS INSTALLATION AND THE POWER CONSUMPTION OF DRIVE MOTORS

Ruslan Rasulovich Mazanov, D Tsyplenkov, Yulia S. Urzhumova, Irina N. Vinokurova
article en

Abstract

Purpose: to substantiate theoretically the impact of the potential energy of suction tube of pumping facilities on the installation mark of the pump axis and the drive motor power. Materials and methods. The theoretical studies were based on the substantiation of the impact of potential energy in the pump housing on head, on the analysis of dependence of hydraulic resistances coefficients in the suction tube on the installation height of the pump axis relative to the water source surface and on the impact of potential energy in the suction tube on the useful power of drive motors. Results. It has been determined that when designing pumping facilities, the pump axis mark and the drive motor power are affected by the potential energy in the suction tube, ranging from positive to negative value. When analyzing the K90/85 pump characteristics, it was found that there was no significant effect of kinetic energy. The main influencing factor on potential energy is the hydraulic resistance coefficient, which varies during operation due to corrosion of the inner surface of the pipeline. When hydraulic resistance coefficient changes from 0.02 to 0.5, the pump axis installation mark ranges from +1.92 to –31.11 m, which leads to a complete stop of the supply feed. Studying the influence of the pipeline length, it was found that the height of the pump axis installation varies from +3.24 to –3.43 m, which indicates the degree of the pumping station building depth. In the study of impact of potential energy on the drive motor power, a decrease from 23.59 to 17.8 kW with a corresponding increase in the total energy in the suction pipeline from 3.28 to 26.92 m was stated. Conclusions: when operating existing and newly designed pumping stations, it should be borne in mind that there is a constant value of the velocity head in the suction pipeline not exceeding 0.2–0.3 m with appropriate diameter selection and the possibility of increasing the coefficient of hydraulic resistance for the inner surface during operation.

Land Reclamation and Hydraulic EngineeringVol. 15(1)
Openalex Percentile: Top 94%
Hydraulic and Pneumatic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

THE POTENTIAL ENERGY IMPACT OF THE SUCTION TUBE OF PUMPING FACILITIES ON THE MARK OF PUMP AXIS INSTALLATION AND THE POWER CONSUMPTION OF DRIVE MOTORS — Ruslan Rasulovich Mazanov, D Tsyplenkov, et al. · Land Reclamation and Hydraulic Engineering (2025) | TGRS Research Map | TGRS