Thermal Evaluation of a Water-to-Air Heat Exchanger Combined with Different Roof Configurations for Passive Cooling

Traditional conservation strategies often prioritize minimizing water use; nevertheless, water can also enhance thermal comfort by incorporating a water-to-air heat exchanger (WAHE) alongside non-direct evaporative and radiant cooling techniques. A WAHE can be installed in features such as ponds, water tanks, or rainwater cisterns. This article assesses the cooling potential of two prototypes of roof ponds and a green roof connected to a WAHE, and the results are compared to a baseline unit featuring a roof that meets California’s energy code standards. Several testing units, measuring 1.35 × 1.35 × 1.35 m, with identical heat characteristics, excluding the roof, were constructed and tested. In the first system, the heat that the green roof could not absorb was transferred to a water reservoir and then dissipated to the outside. The first roof pond prototype features a 0.35 m deep water pond topped with a 0.03 m thick insulating panel and a spray system. The second roof pond variant has an aluminum sheet with a 0.10 m air gap above a 0.25 m deep water pond. The results suggest that combining a WAHE with different roof configurations offers promising benefits while keeping water consumption limited. Notably, when the WAHE is operating, the green roof increase its performance by 47%, the insulated roof pond by 22%, and the roof pond with an aluminum sheet by 13%.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2025-03-27
DOI
https://doi.org/10.3390/buildings15071098
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal Evaluation of a Water-to-Air Heat Exchanger Combined with Different Roof Configurations for Passive Cooling

Pablo La Roche, José Manuel Almodóvar Melendo
Buildings
Adsorption and Cooling Systems
article

Thermal Evaluation of a Water-to-Air Heat Exchanger Combined with Different Roof Configurations for Passive Cooling

Pablo La Roche, José Manuel Almodóvar Melendo
article en

Abstract

Traditional conservation strategies often prioritize minimizing water use; nevertheless, water can also enhance thermal comfort by incorporating a water-to-air heat exchanger (WAHE) alongside non-direct evaporative and radiant cooling techniques. A WAHE can be installed in features such as ponds, water tanks, or rainwater cisterns. This article assesses the cooling potential of two prototypes of roof ponds and a green roof connected to a WAHE, and the results are compared to a baseline unit featuring a roof that meets California’s energy code standards. Several testing units, measuring 1.35 × 1.35 × 1.35 m, with identical heat characteristics, excluding the roof, were constructed and tested. In the first system, the heat that the green roof could not absorb was transferred to a water reservoir and then dissipated to the outside. The first roof pond prototype features a 0.35 m deep water pond topped with a 0.03 m thick insulating panel and a spray system. The second roof pond variant has an aluminum sheet with a 0.10 m air gap above a 0.25 m deep water pond. The results suggest that combining a WAHE with different roof configurations offers promising benefits while keeping water consumption limited. Notably, when the WAHE is operating, the green roof increase its performance by 47%, the insulated roof pond by 22%, and the roof pond with an aluminum sheet by 13%.

BuildingsVol. 15(7)
Universidad de Sevilla (ES), California State Polytechnic University (US)
Universidad de Sevilla
Openalex Percentile: Top 94%
Adsorption and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.