A Monoclonal Antibody-Based Time-Resolved Fluorescence Microsphere Lateral Flow Immunoassay for Dinotefuran and Clothianidin Detection

Dinotefuran and clothianidin belong to the third generation of nicotinic insecticides and are widely used in crop pest control. It is necessary to detect their residues in food. The time-resolved fluorescent microspheres lateral flow immunoassay (TRFMs-LFIA) has the advantages of high sensitivity, short duration, and simple operation and is suitable for rapid field testing. In this study, two haptens (FCA-1, FCA-2) were synthesized in three steps and conjugated to the carrier proteins to obtain artificial antigens, which were subsequently used for monoclonal antibody preparation. A TRFMs-LFIA based on monoclonal antibodies was established to detect dinotefuran and clothianidin residues in food. The limit of detection (LOD) for dinotefuran was 0.045 ng/mL, with an IC<sub>50</sub> of 0.61 ng/mL and a linear range (IC<sub>20</sub>~IC<sub>80</sub>) of 0.12~3.11 ng/mL. The LOD for clothianidin was 0.11 ng/mL, with an IC<sub>50</sub> of 0.94 ng/mL and a linear range (IC<sub>20</sub>~IC<sub>80</sub>) of 0.24~3.65 ng/mL. Cross-reactivity rates with seven tested structural analogs were less than 1.5%. The pretreatment method was optimized for wheat, cucumber, and cabbage samples, which was time-saving (20 min) and easy to operate. The average recovery rates ranged from 88.0% to 114.8%, with the corresponding coefficients of variation appearing (CV) between 1.9% and 13.5%. The results of actual wheat, cucumber, and cabbage samples detected by the established TRFMs-LFIA were consistent with those of Ultra-Performance Liquid Chromatography coupled with Tandem Mass Spectrometry (UPLC-MS/MS). These results demonstrate that the established TRFMs-LFIA is sensitive, accurate, rapid, and suitable for real sample detection.

Authors

Institutions

Publication Details

Journal
Foods
Published
2025-03-27
DOI
https://doi.org/10.3390/foods14071174
Citations
1
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Monoclonal Antibody-Based Time-Resolved Fluorescence Microsphere Lateral Flow Immunoassay for Dinotefuran and Clothianidin Detection

Haojie Chen, Yingxiang Nie, Zhi‐Li Xiao, Ling Qin et al.
1 citations
Foods
Biosensors and Analytical Detection
0.67
article

A Monoclonal Antibody-Based Time-Resolved Fluorescence Microsphere Lateral Flow Immunoassay for Dinotefuran and Clothianidin Detection

Haojie Chen, Yingxiang Nie, Zhi‐Li Xiao, Ling Qin, Junjun Huang, Mengxin Zhou
article en
1 citations

Abstract

Dinotefuran and clothianidin belong to the third generation of nicotinic insecticides and are widely used in crop pest control. It is necessary to detect their residues in food. The time-resolved fluorescent microspheres lateral flow immunoassay (TRFMs-LFIA) has the advantages of high sensitivity, short duration, and simple operation and is suitable for rapid field testing. In this study, two haptens (FCA-1, FCA-2) were synthesized in three steps and conjugated to the carrier proteins to obtain artificial antigens, which were subsequently used for monoclonal antibody preparation. A TRFMs-LFIA based on monoclonal antibodies was established to detect dinotefuran and clothianidin residues in food. The limit of detection (LOD) for dinotefuran was 0.045 ng/mL, with an IC<sub>50</sub> of 0.61 ng/mL and a linear range (IC<sub>20</sub>~IC<sub>80</sub>) of 0.12~3.11 ng/mL. The LOD for clothianidin was 0.11 ng/mL, with an IC<sub>50</sub> of 0.94 ng/mL and a linear range (IC<sub>20</sub>~IC<sub>80</sub>) of 0.24~3.65 ng/mL. Cross-reactivity rates with seven tested structural analogs were less than 1.5%. The pretreatment method was optimized for wheat, cucumber, and cabbage samples, which was time-saving (20 min) and easy to operate. The average recovery rates ranged from 88.0% to 114.8%, with the corresponding coefficients of variation appearing (CV) between 1.9% and 13.5%. The results of actual wheat, cucumber, and cabbage samples detected by the established TRFMs-LFIA were consistent with those of Ultra-Performance Liquid Chromatography coupled with Tandem Mass Spectrometry (UPLC-MS/MS). These results demonstrate that the established TRFMs-LFIA is sensitive, accurate, rapid, and suitable for real sample detection.

FoodsVol. 14(7)
South China Agricultural University (CN)
Openalex Percentile: Top 33%
Biosensors and Analytical Detection
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Monoclonal Antibody-Based Time-Resolved Fluorescence Microsphere Lateral Flow Immunoassay for Dinotefuran and Clothianidin Detection — Haojie Chen, Yingxiang Nie, et al. · Foods (2025) | TGRS Research Map | TGRS