Background: Accurate prognoses are challenging in high-risk vascular conditions, such as abdominal aortic aneurysms, and limited diagnostic standards, decision-making criteria, and data semantics often hinder clinical reliability and impede diagnostics’ digital transition. This study aims to evaluate the performance, robustness, and usability of an automatic, replicable pipeline for aortic lumen surface reconstruction for pathological vessels. The goal is to provide a solid tool for geometric reconstruction to a more complex enhanced diagnostic framework. Methods: A U-Net convolutional neural network is trained using preoperative CTA scans, with 101 for model training and 14 for model testing, covering a wide anatomical and aortoiliac pathology spectrum. Validation included segmentation metric, robustness, reliability, and usability assessments. Performances are investigated by means of the test set’s prediction metrics for several instances of the model’s input. Clinical reliability is evaluated based on manual measurements performed by a vascular surgeon on the obtained 3D aortic lumen surfaces. Results: The test set is selected to cover a wide portion of aortoiliac pathologies. The algorithm demonstrated robustness with an average F1-score of 0.850 ± 0.120 and an intersection over union score of 0.760 ± 0.150 in the test set. Clinical reliability is assessed using the mean absolute errors for diameter and length measurements, respectively, of 1.73 mm and 2.27 mm. The 3D surface reconstruction demonstrated reliability, low processing times, and clinically valid reconstructions. Conclusions: The proposed algorithm can correctly reconstruct pathological vessels. Secondary aortoiliac pathologies are detected properly for challenging anatomies. To conclude, the proposed 3D reconstruction application to a digital, patient-specific diagnostic tool is, therefore, possible. Automatic replicable pipelines ensured the usability of the model’s outputs.

Authors

Institutions

Publication Details

Journal
BioMed
Published
2025-03-25
DOI
https://doi.org/10.3390/biomed5020009
Citations
1
Primary Topic
Aortic aneurysm repair treatments
Type
article
Field-Weighted Citation Impact
1.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of Replicable Pipeline 3D Surface Reconstruction for Patient-Specific Abdominal Aortic Lumen Diagnostics

Mauro Gargiulo, Giorgio La Civita, Giuseppe Lisanti, Edoardo Ugolini et al.
1 citations
BioMed
Aortic aneurysm repair treatments
1.52
article

Validation of Replicable Pipeline 3D Surface Reconstruction for Patient-Specific Abdominal Aortic Lumen Diagnostics

Mauro Gargiulo, Giorgio La Civita, Giuseppe Lisanti, Edoardo Ugolini, Gianluca Faggioli, Samuele Salti, Emanuele Ghedini, Giovanni Rossi, Moad Al Aidroos
article en
1 citations

Abstract

Background: Accurate prognoses are challenging in high-risk vascular conditions, such as abdominal aortic aneurysms, and limited diagnostic standards, decision-making criteria, and data semantics often hinder clinical reliability and impede diagnostics’ digital transition. This study aims to evaluate the performance, robustness, and usability of an automatic, replicable pipeline for aortic lumen surface reconstruction for pathological vessels. The goal is to provide a solid tool for geometric reconstruction to a more complex enhanced diagnostic framework. Methods: A U-Net convolutional neural network is trained using preoperative CTA scans, with 101 for model training and 14 for model testing, covering a wide anatomical and aortoiliac pathology spectrum. Validation included segmentation metric, robustness, reliability, and usability assessments. Performances are investigated by means of the test set’s prediction metrics for several instances of the model’s input. Clinical reliability is evaluated based on manual measurements performed by a vascular surgeon on the obtained 3D aortic lumen surfaces. Results: The test set is selected to cover a wide portion of aortoiliac pathologies. The algorithm demonstrated robustness with an average F1-score of 0.850 ± 0.120 and an intersection over union score of 0.760 ± 0.150 in the test set. Clinical reliability is assessed using the mean absolute errors for diameter and length measurements, respectively, of 1.73 mm and 2.27 mm. The 3D surface reconstruction demonstrated reliability, low processing times, and clinically valid reconstructions. Conclusions: The proposed algorithm can correctly reconstruct pathological vessels. Secondary aortoiliac pathologies are detected properly for challenging anatomies. To conclude, the proposed 3D reconstruction application to a digital, patient-specific diagnostic tool is, therefore, possible. Automatic replicable pipelines ensured the usability of the model’s outputs.

BioMedVol. 5(2)
IRCCS Azienda Ospedliero-Universitaria di Bologna Policlinico di Sant'Orsola (IT), Alessandro Manzoni Hospital (IT), University of Bologna (IT)
Openalex Percentile: Top 20%
Aortic aneurysm repair treatments
1.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.