Proposal for a Method for Assessing the Quality of an Updated Deep Learning-Based Automatic Segmentation Program

This study aimed to verify whether a commercial deep learning-based automatic segmentation (DLS) method can maintain contour geometric accuracy post-update and to propose a streamlined validation method that minimizes the burden on clinical workflows. This study included 109 participants. Radiation oncologists used computed tomography (CT) imaging to identify 28 organs located in the head and neck, chest, abdomen, and pelvic regions. Contours were delineated on CT images using AI-Rad Companion Organs RT (AIRC; Siemens Healthineers, Erlangen, Germany) versions VA30, VA50, and VA50. The Dice similarity coefficient, maximum Hausdorff distance, and mean distance to agreement were calculated to identify contours with significant differences among versions. To evaluate the identified contours, the ground truth was defined as the contour delineated by radiation oncologists, and the geometric indices for VA30, VA50, and VA60 were recalculated. Statistical analysis was performed on the geometric indices to verify differences between each version. Among the 28 contours evaluated, nine organs did not satisfy the established criteria. Statistical analysis revealed that the brain, rectum, and bladder contours differed substantially across AIRC versions. In particular, the pre-update rectum contour had a mean (range) Hausdorff distance of 0.76 (0.40-1.16), whereas the post-update rectum contour exhibited lower quality, with a Hausdorff distance of 1.13 (0.24-5.68). Therefore, commercial DLS methods that undergo regular updates must be reassessed for quality in each region of interest. The proposed method can help reduce the burden on clinical workflows while appropriately evaluating post-update DLS performance.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-03-27
DOI
https://doi.org/10.7759/cureus.81307
Citations
1
Primary Topic
Advanced Neural Network Applications
Type
article
Field-Weighted Citation Impact
1.28
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Proposal for a Method for Assessing the Quality of an Updated Deep Learning-Based Automatic Segmentation Program

M Hirano, Ryohei Yamauchi, Satoshi Ishikura, Fumihiro Tomita et al.
1 citations
Cureus
Advanced Neural Network Applications
1.28
article

Proposal for a Method for Assessing the Quality of an Updated Deep Learning-Based Automatic Segmentation Program

M Hirano, Ryohei Yamauchi, Satoshi Ishikura, Fumihiro Tomita, Tomoyuki Masuda, Shinobu Akiyama
article en
1 citations

Abstract

This study aimed to verify whether a commercial deep learning-based automatic segmentation (DLS) method can maintain contour geometric accuracy post-update and to propose a streamlined validation method that minimizes the burden on clinical workflows. This study included 109 participants. Radiation oncologists used computed tomography (CT) imaging to identify 28 organs located in the head and neck, chest, abdomen, and pelvic regions. Contours were delineated on CT images using AI-Rad Companion Organs RT (AIRC; Siemens Healthineers, Erlangen, Germany) versions VA30, VA50, and VA50. The Dice similarity coefficient, maximum Hausdorff distance, and mean distance to agreement were calculated to identify contours with significant differences among versions. To evaluate the identified contours, the ground truth was defined as the contour delineated by radiation oncologists, and the geometric indices for VA30, VA50, and VA60 were recalculated. Statistical analysis was performed on the geometric indices to verify differences between each version. Among the 28 contours evaluated, nine organs did not satisfy the established criteria. Statistical analysis revealed that the brain, rectum, and bladder contours differed substantially across AIRC versions. In particular, the pre-update rectum contour had a mean (range) Hausdorff distance of 0.76 (0.40-1.16), whereas the post-update rectum contour exhibited lower quality, with a Hausdorff distance of 1.13 (0.24-5.68). Therefore, commercial DLS methods that undergo regular updates must be reassessed for quality in each region of interest. The proposed method can help reduce the burden on clinical workflows while appropriately evaluating post-update DLS performance.

CureusVol. 17(3)
St. Luke's International Hospital (JP)
Openalex Percentile: Top 22%
Advanced Neural Network Applications
1.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.