The preclinical study of biocompatibility of tyrosine polycarbonate bioresorbable scaffold in small caliber porcine peripheral arteries

Drug-eluting resorbable scaffolds (DRS) are conceptually attractive for treatment of peripheral arterial disease, particularly below-the-knee. MOTIV is a peripheral variant of REVA Medical's well-established, radiopaque tyrosine-polycarbonate (Tyrocore) sirolimus-eluting DRS. The purpose of this study was to provide imaging and histopathologic data on vascular response to MOTIV in porcine peripheral arteries. MOTIV scaffolds (3.0 or 3.5 × 12/24/36/48/60 mm) were implanted in 20 internal iliac arteries of 9 Yorkshire swine. At 30 and 90 days, vascular stenosis, strut coverage, and strut apposition were characterized using optical coherence tomography. Scaffold structure and vascular healing were assessed by histopathology and scanning electron microscopy. At termination, all vessels remained patent. The average neointimal thickness was 0.22 ± 0.05 mm in Group 1 (30 days) and 0.18 ± 0.10 mm in Group 2 (90 days); the percent area stenosis was 28 ± 6% and 24 ± 11%, respectively. All struts were fully covered by neointima. No malapposition, stent fracture or late strut discontinuity was observed. Adequate vessel wall healing at both time points was characterized by a typically fully mature neointima and complete reendothelialization at all sites. No unresorbed luminal thrombus was observed. The inflammation scores were low for all vessels on both time points, except for one animal. The average inflammation (excluding multinucleated giant cells [MNGCs]) was 0.6 (MNGCs score was 0.9) for the stented vessel segments at 30 days and 0.8 (MNGCs score of 1.0) at 90 days. Implantation of the MOTIV up to 60 mm long in small-caliber peripheral arteries of swine resulted in 100% patency rate and adequate vascular healing at 30-day and 90-day timepoints. The Tyrocore-based DRS retained the necessary structural integrity throughout the course of the study and confirmed their favorable biocompatibility in small-caliber porcine peripheral arteries.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-03-27
DOI
https://doi.org/10.1038/s41598-025-91759-6
Citations
4
Primary Topic
Peripheral Artery Disease Management
Type
article
Field-Weighted Citation Impact
8.03
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The preclinical study of biocompatibility of tyrosine polycarbonate bioresorbable scaffold in small caliber porcine peripheral arteries

Pedro Melo, Juan F. Granada, Yanping Cheng, Sahil A. Parikh et al.
4 citations
Scientific Reports
Peripheral Artery Disease Management
8.03
article

The preclinical study of biocompatibility of tyrosine polycarbonate bioresorbable scaffold in small caliber porcine peripheral arteries

Pedro Melo, Juan F. Granada, Yanping Cheng, Sahil A. Parikh, Serge Rousselle, Mateusz Kachel, Grzegorz L. Kałuża, Gerard Conditt, Danielle Gram, Jeffrey Anderson
article en
4 citations

Abstract

Drug-eluting resorbable scaffolds (DRS) are conceptually attractive for treatment of peripheral arterial disease, particularly below-the-knee. MOTIV is a peripheral variant of REVA Medical's well-established, radiopaque tyrosine-polycarbonate (Tyrocore) sirolimus-eluting DRS. The purpose of this study was to provide imaging and histopathologic data on vascular response to MOTIV in porcine peripheral arteries. MOTIV scaffolds (3.0 or 3.5 × 12/24/36/48/60 mm) were implanted in 20 internal iliac arteries of 9 Yorkshire swine. At 30 and 90 days, vascular stenosis, strut coverage, and strut apposition were characterized using optical coherence tomography. Scaffold structure and vascular healing were assessed by histopathology and scanning electron microscopy. At termination, all vessels remained patent. The average neointimal thickness was 0.22 ± 0.05 mm in Group 1 (30 days) and 0.18 ± 0.10 mm in Group 2 (90 days); the percent area stenosis was 28 ± 6% and 24 ± 11%, respectively. All struts were fully covered by neointima. No malapposition, stent fracture or late strut discontinuity was observed. Adequate vessel wall healing at both time points was characterized by a typically fully mature neointima and complete reendothelialization at all sites. No unresorbed luminal thrombus was observed. The inflammation scores were low for all vessels on both time points, except for one animal. The average inflammation (excluding multinucleated giant cells [MNGCs]) was 0.6 (MNGCs score was 0.9) for the stented vessel segments at 30 days and 0.8 (MNGCs score of 1.0) at 90 days. Implantation of the MOTIV up to 60 mm long in small-caliber peripheral arteries of swine resulted in 100% patency rate and adequate vascular healing at 30-day and 90-day timepoints. The Tyrocore-based DRS retained the necessary structural integrity throughout the course of the study and confirmed their favorable biocompatibility in small-caliber porcine peripheral arteries.

Scientific ReportsVol. 15(1)
Columbia University Irving Medical Center (US), Reva Medical (United States) (US), American Heart of Poland (PL), Center for Innovation (US), Cardiovascular Research Foundation (US)
Openalex Percentile: Top 3%
Peripheral Artery Disease Management
8.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.