A Robot for Transcanal Endoscopic Ear Surgery with Gimbal-based Rotational Linkage and Linear Guide Rail Mechanisms

Transcanal endoscopic ear surgery (TEES) is a minimally invasive approach for treating ear diseases. TEES requires simultaneous insertion of an endoscope and surgical instruments through the narrow external auditory canal (less than 1 cm in diameter). Due to this anatomical constraint, conventional TEES has limitations including one-handed instrument manipulation and endoscope instability. We developed a compact, bed rail-mounted endoscope manipulator to enable two-handed surgery. The manipulator features three degrees of freedom: yaw and pitch movements controlled by gimbal rotational linkages, and insertion facilitated by a linear guide rail. We evaluated the mechanical performance of the prototype using an optical displacement sensor, and demonstrated positional accuracy within 0.1 mm across all axes under a 6-N load. Functionality of the manipulator was verified by cadaver trials and an ear canal model simulation. Five otolaryngologists performed a simulated surgical task using both manual and robot-assisted endoscopic procedures. While there was no significant difference in task completion time between manual and robot-assisted methods, less experienced surgeons showed improved performance and reduced time variability with the robot. The manipulator demonstrated satisfactory performance, meeting the dexterity and precision required for ear surgery. This novel endoscope-holding robot shows potential to enhance surgical precision and efficiency in TEES, particularly benefiting less experienced surgeons. Future iterations will aim to optimize its form factor and functional complexity to enhance clinical utility.

Authors

Institutions

Publication Details

Journal
Advanced Biomedical Engineering
Published
2025-01-01
DOI
https://doi.org/10.14326/abe.14.146
Citations
2
Primary Topic
Tracheal and airway disorders
Type
article
Field-Weighted Citation Impact
3.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Robot for Transcanal Endoscopic Ear Surgery with Gimbal-based Rotational Linkage and Linear Guide Rail Mechanisms

Toshihiko YAMASHITA, Hisashi Suzuki, Kunio Mizutari, Akinobu Kakigi et al.
2 citations
Advanced Biomedical Engineering
Tracheal and airway disorders
3.04
article

A Robot for Transcanal Endoscopic Ear Surgery with Gimbal-based Rotational Linkage and Linear Guide Rail Mechanisms

Toshihiko YAMASHITA, Hisashi Suzuki, Kunio Mizutari, Akinobu Kakigi, Ken‐ichi Nibu, Atsushi Nishikawa, Kenta YOKOYAMA, Natsumi UEHARA, Takefumi Kamakura, Toshikazu KAWAI, Yu Matsumoto, Takeshi FUJITA
article en
2 citations

Abstract

Transcanal endoscopic ear surgery (TEES) is a minimally invasive approach for treating ear diseases. TEES requires simultaneous insertion of an endoscope and surgical instruments through the narrow external auditory canal (less than 1 cm in diameter). Due to this anatomical constraint, conventional TEES has limitations including one-handed instrument manipulation and endoscope instability. We developed a compact, bed rail-mounted endoscope manipulator to enable two-handed surgery. The manipulator features three degrees of freedom: yaw and pitch movements controlled by gimbal rotational linkages, and insertion facilitated by a linear guide rail. We evaluated the mechanical performance of the prototype using an optical displacement sensor, and demonstrated positional accuracy within 0.1 mm across all axes under a 6-N load. Functionality of the manipulator was verified by cadaver trials and an ear canal model simulation. Five otolaryngologists performed a simulated surgical task using both manual and robot-assisted endoscopic procedures. While there was no significant difference in task completion time between manual and robot-assisted methods, less experienced surgeons showed improved performance and reduced time variability with the robot. The manipulator demonstrated satisfactory performance, meeting the dexterity and precision required for ear surgery. This novel endoscope-holding robot shows potential to enhance surgical precision and efficiency in TEES, particularly benefiting less experienced surgeons. Future iterations will aim to optimize its form factor and functional complexity to enhance clinical utility.

Advanced Biomedical EngineeringVol. 14(0)
Tokyo Metropolitan Police Hospital (JP), National Defense Medical College (JP), Kobe University (JP), Osaka Institute of Technology (JP), Chuo University (JP), The University of Osaka (JP)
Openalex Percentile: Top 10%
Tracheal and airway disorders
3.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.