Intermediate thermomechanical analysis and optimization of the ITER Upper port mounted bolometer camera

The bolometer diagnostic system in the ITER monitors the plasma radiation from multiple positions inside the vacuum vessel for a complete measurement. The cameras are named according to their locations, like the port plug (PP) cameras and the divertor ones. This paper is about the cameras in the upper port plug. Because of the severe working environment, especially the high neutron and gamma heating power and the electromagnetic (EM) forces during the plasma disruptions, the camera structure has two functions: 1) in the thermal point of view, the heat deposited on the sensors needs to be effectively exhausted; 2) in the structural point of view, the camera must keep in position under various of mechanical loads. Due to limited space, passive cooling methodology is chosen, in which the camera housing conducts the heat to the Diagnostic Shield Module (DSM), so a thick metallic housing is helpful in both neutron shielding and heat conduction. However, during disruptions these thick walls will induce strong eddy currents and cause high EM forces. Additionally, the mechanical constraints, in order to resist these dynamic EM loads, generate high thermal loads on the camera. Therefore, the design optimization must carefully find a balance among all relevant issues. The port plug design has been finished and provides the attachment boundary conditions for the camera analysis, but the information is not detailed enough, then the camera finite element (FE) model is integrated into the existing PP FE model for a seamless interface. The methodology and intermediate results of the thermomechanical analysis are presented, and the experience gained are also applicable for similarly attached in-vessel components.

Authors

Institutions

Publication Details

Journal
Fusion Engineering and Design
Published
2025-03-27
DOI
https://doi.org/10.1016/j.fusengdes.2025.114997
Primary Topic
Calibration and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intermediate thermomechanical analysis and optimization of the ITER Upper port mounted bolometer camera

N. Jaksic, M.A. Villarejo, Z. Wang, Á. Pataki et al.
Fusion Engineering and Design
Calibration and Measurement Techniques
article

Intermediate thermomechanical analysis and optimization of the ITER Upper port mounted bolometer camera

N. Jaksic, M.A. Villarejo, Z. Wang, Á. Pataki, H. Meister
article en

Abstract

The bolometer diagnostic system in the ITER monitors the plasma radiation from multiple positions inside the vacuum vessel for a complete measurement. The cameras are named according to their locations, like the port plug (PP) cameras and the divertor ones. This paper is about the cameras in the upper port plug. Because of the severe working environment, especially the high neutron and gamma heating power and the electromagnetic (EM) forces during the plasma disruptions, the camera structure has two functions: 1) in the thermal point of view, the heat deposited on the sensors needs to be effectively exhausted; 2) in the structural point of view, the camera must keep in position under various of mechanical loads. Due to limited space, passive cooling methodology is chosen, in which the camera housing conducts the heat to the Diagnostic Shield Module (DSM), so a thick metallic housing is helpful in both neutron shielding and heat conduction. However, during disruptions these thick walls will induce strong eddy currents and cause high EM forces. Additionally, the mechanical constraints, in order to resist these dynamic EM loads, generate high thermal loads on the camera. Therefore, the design optimization must carefully find a balance among all relevant issues. The port plug design has been finished and provides the attachment boundary conditions for the camera analysis, but the information is not detailed enough, then the camera finite element (FE) model is integrated into the existing PP FE model for a seamless interface. The methodology and intermediate results of the thermomechanical analysis are presented, and the experience gained are also applicable for similarly attached in-vessel components.

Fusion Engineering and DesignVol. 215
Max Planck Institute for Plasma Physics (DE), Fusion for Energy (ES)
Fusion for Energy
Affordable and clean energy
Openalex Percentile: Top 92%
Calibration and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.