A ratiometric fluorescent platform based on xylan-derived carbon dots for detecting Vibrio parahaemolyticus

It is a challenge to design a ratiometric fluorescent platform with a stable inner reference free from disturbing for detection. Herein, a ratiometric fluorescent platform (RFP) was fabricated for detection of Vibrio parahaemolyticus ( V. parahaemolyticus ) based on optically transparent silica nanoparticles which integrates fluorophores and specific aptamers. The platform incorporated Rhodamine B as an internal reference within the protective silica matrix, while xylan-derived carbon dots were evenly distributed on silica’s surface. When excited at 365 nm, RFP exhibited blue fluorescence at 430 nm and orange fluorescence at 575 nm. Blue fluorescence of these carbon dots was quenched through interaction with a Dabcyl-modified aptamer (Apt.D). Upon bacterial addition, changes in the fluorescence intensities were observed, enabling sensitive and ratiometric detection. Notably, this RFP-Apt.D has a low detection limit of 1.15 CFU/mL (S/N = 3) with a linear detection range from 8 CFU/mL to 8 ×10 5 CFU/mL in a short responding time of 30 minutes, which was superior to most reported V. parahaemolyticus sensors. Furthermore, the RFP-Apt.D was successfully applied to detect V. parahaemolyticus in seawater and clam samples through a fast pretreatment without requiring enrichment and achieved reliable and satisfactory recoveries. This work provides a widely adaptable platform to design ratiometric fluorescent sensor for detection of foodborne pathogen. • Xylan-based carbon dots was used to fabricate ratiometric fluorescent platform. • Fluorescence at 432, 575 nm provides internal ratio calibration against interference. • The transparent silica nanoparticles improve the stability of fluorescent reference. • The fluorescent platform shows trace detection for Vibrio parahaemolyticus . • Linear detection range is 8–8 × 10 5 CFU/mL with LOD of 1.15 CFU/mL in 30 min.

Authors

Institutions

Publication Details

Journal
Industrial Crops and Products
Published
2025-03-27
DOI
https://doi.org/10.1016/j.indcrop.2025.120871
Citations
9
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
6.07

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A ratiometric fluorescent platform based on xylan-derived carbon dots for detecting Vibrio parahaemolyticus

Jihai Cai, Xiaoying Wang, Shanshan Yu, Xiwen Feng
9 citations
Industrial Crops and Products
Biosensors and Analytical Detection
6.07
article

A ratiometric fluorescent platform based on xylan-derived carbon dots for detecting Vibrio parahaemolyticus

Jihai Cai, Xiaoying Wang, Shanshan Yu, Xiwen Feng
article en
9 citations

Abstract

It is a challenge to design a ratiometric fluorescent platform with a stable inner reference free from disturbing for detection. Herein, a ratiometric fluorescent platform (RFP) was fabricated for detection of Vibrio parahaemolyticus ( V. parahaemolyticus ) based on optically transparent silica nanoparticles which integrates fluorophores and specific aptamers. The platform incorporated Rhodamine B as an internal reference within the protective silica matrix, while xylan-derived carbon dots were evenly distributed on silica’s surface. When excited at 365 nm, RFP exhibited blue fluorescence at 430 nm and orange fluorescence at 575 nm. Blue fluorescence of these carbon dots was quenched through interaction with a Dabcyl-modified aptamer (Apt.D). Upon bacterial addition, changes in the fluorescence intensities were observed, enabling sensitive and ratiometric detection. Notably, this RFP-Apt.D has a low detection limit of 1.15 CFU/mL (S/N = 3) with a linear detection range from 8 CFU/mL to 8 ×10 5 CFU/mL in a short responding time of 30 minutes, which was superior to most reported V. parahaemolyticus sensors. Furthermore, the RFP-Apt.D was successfully applied to detect V. parahaemolyticus in seawater and clam samples through a fast pretreatment without requiring enrichment and achieved reliable and satisfactory recoveries. This work provides a widely adaptable platform to design ratiometric fluorescent sensor for detection of foodborne pathogen. • Xylan-based carbon dots was used to fabricate ratiometric fluorescent platform. • Fluorescence at 432, 575 nm provides internal ratio calibration against interference. • The transparent silica nanoparticles improve the stability of fluorescent reference. • The fluorescent platform shows trace detection for Vibrio parahaemolyticus . • Linear detection range is 8–8 × 10 5 CFU/mL with LOD of 1.15 CFU/mL in 30 min.

Industrial Crops and ProductsVol. 228
South China University of Technology (CN)
National Natural Science Foundation of China, China Postdoctoral Science Foundation, Basic and Applied Basic Research Foundation of Guangdong Province
Openalex Percentile: Top 4%
Biosensors and Analytical Detection
6.07
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.