Motorised bionic arms using SSVEP with enhanced hand gesture accuracy and reliability

The development of motorised bionic arms has been a significant focus in prosthetics. This study explored the design and implementation of a motorised bionic arm, with particular emphasis on enhanced hand gesture accuracy and reliability. Initially, the functional circuit and algorithm were designed, followed by the development of a motorised framework to control a 3D-printed real-time bionic arm, utilising steady state visually evoked potential (SSVEP) stimuli. The system's effectiveness was evaluated through accuracy and reliability tests on repeatability of gestures such as hand open, hand close, thumb up, and pointing, induced by four flickering frequencies between the range of (10–20 Hz). Findings revealed a mean accuracy of 97.5%, with individual accuracy rates ranging from 88.75% to 100%. Over the 30 tests, average angles were 168.8° (pointing), 169° (thumb up), 174.5° (open), and 132.17° (close), demonstrating consistent performance. These results contribute valuable insights into the design, control, and evaluation of motorised prosthetic devices, providing users with a more intuitive and reliable means of restoring hand functionality.

Authors

Institutions

Publication Details

Journal
International Journal of Biomedical Engineering and Technology
Published
2025-01-01
DOI
https://doi.org/10.1504/ijbet.2025.145218
Primary Topic
Hand Gesture Recognition Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Motorised bionic arms using SSVEP with enhanced hand gesture accuracy and reliability

Tan Tian Swee, Michael Loong Peng Tan, Maheza Irna Mohamad Salim, Jahanzeb Sheikh et al.
International Journal of Biomedical Engineering and Technology
Hand Gesture Recognition Systems
article

Motorised bionic arms using SSVEP with enhanced hand gesture accuracy and reliability

Tan Tian Swee, Michael Loong Peng Tan, Maheza Irna Mohamad Salim, Jahanzeb Sheikh, Yan Chai Hum, Tengku Ahmad T. Alang
article en

Abstract

The development of motorised bionic arms has been a significant focus in prosthetics. This study explored the design and implementation of a motorised bionic arm, with particular emphasis on enhanced hand gesture accuracy and reliability. Initially, the functional circuit and algorithm were designed, followed by the development of a motorised framework to control a 3D-printed real-time bionic arm, utilising steady state visually evoked potential (SSVEP) stimuli. The system's effectiveness was evaluated through accuracy and reliability tests on repeatability of gestures such as hand open, hand close, thumb up, and pointing, induced by four flickering frequencies between the range of (10–20 Hz). Findings revealed a mean accuracy of 97.5%, with individual accuracy rates ranging from 88.75% to 100%. Over the 30 tests, average angles were 168.8° (pointing), 169° (thumb up), 174.5° (open), and 132.17° (close), demonstrating consistent performance. These results contribute valuable insights into the design, control, and evaluation of motorised prosthetic devices, providing users with a more intuitive and reliable means of restoring hand functionality.

International Journal of Biomedical Engineering and TechnologyVol. 47(4)
University of Cyberjaya (MY), University of Technology Malaysia (MY), Universiti Tunku Abdul Rahman (MY)
Affordable and clean energy
Openalex Percentile: Top 96%
Hand Gesture Recognition Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Motorised bionic arms using SSVEP with enhanced hand gesture accuracy and reliability — Tan Tian Swee, Michael Loong Peng Tan, et al. · International Journal of Biomedical Engineering and Technology (2025) | TGRS Research Map | TGRS