Bicycle Pedal Angle Measurements Using Model With Wireless Motion Sensors

Recently, research has focused on the ankle joint and pedal angles. Therefore, we measured the change in pedal angle in the horizontal plane, revealing a difference in pedaling characteristics. In this study, a computational model was proposed to accurately measure the rotation angles of both bicycle pedals. The system consisted of three wireless motion sensors with biaxial acceleration and an angular velocity sensor attached to the crank arm and both pedals. The rotational pedal angles measured by the motion sensors were compared with data from a motion-capture system. The root-mean-square error for the bicycle pedal angle was 0.429 ± 0.138° (mean ± SD), and the correlation coefficient was 0.9996 for the combined pedals. Using the proposed computational model, both pedal angles were measured with the same accuracy as that of the motion-capture system but with a higher frequency.

Authors

Institutions

Publication Details

Journal
IFAC-PapersOnLine
Published
2025-01-01
DOI
https://doi.org/10.1016/j.ifacol.2025.03.036
Primary Topic
Indoor and Outdoor Localization Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bicycle Pedal Angle Measurements Using Model With Wireless Motion Sensors

Masahiro Fukuda, Tomoki Kitawaki
IFAC-PapersOnLine
Indoor and Outdoor Localization Technologies
article

Bicycle Pedal Angle Measurements Using Model With Wireless Motion Sensors

Masahiro Fukuda, Tomoki Kitawaki
article en

Abstract

Recently, research has focused on the ankle joint and pedal angles. Therefore, we measured the change in pedal angle in the horizontal plane, revealing a difference in pedaling characteristics. In this study, a computational model was proposed to accurately measure the rotation angles of both bicycle pedals. The system consisted of three wireless motion sensors with biaxial acceleration and an angular velocity sensor attached to the crank arm and both pedals. The rotational pedal angles measured by the motion sensors were compared with data from a motion-capture system. The root-mean-square error for the bicycle pedal angle was 0.429 ± 0.138° (mean ± SD), and the correlation coefficient was 0.9996 for the combined pedals. Using the proposed computational model, both pedal angles were measured with the same accuracy as that of the motion-capture system but with a higher frequency.

IFAC-PapersOnLineVol. 59(1)
Kansai Medical University (JP), Okayama University (JP), British Cycling (GB)
Affordable and clean energy
Openalex Percentile: Top 95%
Indoor and Outdoor Localization Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Bicycle Pedal Angle Measurements Using Model With Wireless Motion Sensors — Masahiro Fukuda, Tomoki Kitawaki · IFAC-PapersOnLine (2025) | TGRS Research Map | TGRS