Efficacy of Leadless Ultrasound-Based Left Ventricular Endocardial Pacing for Cardiac Resynchronization Therapy: A Meta-Analysis

Heart failure with reduced ejection fraction is a major cause of morbidity and mortality. Cardiac resynchronization therapy (CRT) improves outcomes but faces challenges such as unsuccessful lead placement and suboptimal responses. The Wireless Stimulation Endocardially for CRT (WiSE-CRT) system, a novel leadless left ventricular (LV) pacing technology, uses ultrasonic energy to deliver electrical stimulation directly to the LV endocardium, potentially improving the response rates. A comprehensive literature search was performed across multiple databases from inception until August 2024. The outcomes of interest included the New York Heart Association (NYHA) functional score, LV ejection fraction (LVEF), LV end-diastolic volume (LVEDV), LV end-systolic volume (LVESV), and QRS duration. Statistical analysis involved pooling the mean differences (MDs) and their corresponding 95% confidence intervals (CIs) from each study using the inverse-variance random-effects model in RevMan version 5.4.1 software. Seven studies, including 468 patients with heart failure treated with the WiSE-CRT system, were included. The pooled analysis showed significant improvements in NYHA functional score (MD: -0.44; 95% CI: -0.67 to -0.21; P = 0.0002; I2 = 77%), LVEF (MD: 5.71; 95% CI: 4.54 to 6.87; P < 0.001), LVEDV (MD: -24.49; 95% CI: -33.24 to -15.73; P < 0.001), and LVESV (MD: -24.47; 95% CI: -32.80 to -16.14; P < 0.001). The QRS duration also decreased significantly (MD: -38.62; 95% CI: -46.76 to -30.49; P < 0.001; I2 = 60%). The WiSE-CRT system significantly improved NYHA functional score, LVEF, QRS duration, LVEDV, and LVESV in patients with heart failure. This leadless pacing technology offers a promising alternative for ineligible candidates or for those who do not respond to conventional CRT.

Authors

Institutions

Publication Details

Journal
Cardiology in Review
Published
2025-03-26
DOI
https://doi.org/10.1097/crd.0000000000000897
Citations
1
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
1.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficacy of Leadless Ultrasound-Based Left Ventricular Endocardial Pacing for Cardiac Resynchronization Therapy: A Meta-Analysis

Hritvik Jain, Mushood Ahmed, Abdul Moiz Khan, C. Anwar A. Chahal et al.
1 citations
Cardiology in Review
Cardiac pacing and defibrillation studies
1.39
article

Efficacy of Leadless Ultrasound-Based Left Ventricular Endocardial Pacing for Cardiac Resynchronization Therapy: A Meta-Analysis

Hritvik Jain, Mushood Ahmed, Abdul Moiz Khan, C. Anwar A. Chahal, Rui Providência, Eeshal Zulfiqar, Siddharth Shah, Jyoti Jain, Jagjot Singh, Muhammad Daoud Tariq, Syed Khurram Mushtaq Gardezi, Raheel Ahmed, Nandan Patel
article en
1 citations

Abstract

Heart failure with reduced ejection fraction is a major cause of morbidity and mortality. Cardiac resynchronization therapy (CRT) improves outcomes but faces challenges such as unsuccessful lead placement and suboptimal responses. The Wireless Stimulation Endocardially for CRT (WiSE-CRT) system, a novel leadless left ventricular (LV) pacing technology, uses ultrasonic energy to deliver electrical stimulation directly to the LV endocardium, potentially improving the response rates. A comprehensive literature search was performed across multiple databases from inception until August 2024. The outcomes of interest included the New York Heart Association (NYHA) functional score, LV ejection fraction (LVEF), LV end-diastolic volume (LVEDV), LV end-systolic volume (LVESV), and QRS duration. Statistical analysis involved pooling the mean differences (MDs) and their corresponding 95% confidence intervals (CIs) from each study using the inverse-variance random-effects model in RevMan version 5.4.1 software. Seven studies, including 468 patients with heart failure treated with the WiSE-CRT system, were included. The pooled analysis showed significant improvements in NYHA functional score (MD: -0.44; 95% CI: -0.67 to -0.21; P = 0.0002; I2 = 77%), LVEF (MD: 5.71; 95% CI: 4.54 to 6.87; P < 0.001), LVEDV (MD: -24.49; 95% CI: -33.24 to -15.73; P < 0.001), and LVESV (MD: -24.47; 95% CI: -32.80 to -16.14; P < 0.001). The QRS duration also decreased significantly (MD: -38.62; 95% CI: -46.76 to -30.49; P < 0.001; I2 = 60%). The WiSE-CRT system significantly improved NYHA functional score, LVEF, QRS duration, LVEDV, and LVESV in patients with heart failure. This leadless pacing technology offers a promising alternative for ineligible candidates or for those who do not respond to conventional CRT.

Cardiology in Review
St Bartholomew's Hospital (GB), Ayub Medical College (PK), Rawalpindi Medical University (PK), Khalifa University of Science and Technology (AE), All India Institute of Medical Sciences Jodhpur (IN), Barts Health NHS Trust (GB), Government Medical College, Amritsar (IN), Foundation University Medical College (PK), Rajarshee Chhatrapati Shahu Maharaj Government Medical College and CPR Hospital Kolhapur (IN), British Heart Foundation (GB), Dow University of Health Sciences (PK), WellSpan Health (US), Mayo Clinic in Arizona (US), Imperial College London (GB)
Good health and well-being
Openalex Percentile: Top 21%
Cardiac pacing and defibrillation studies
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.