Co/Zn ZIFs with MXene and MWCNTs nanocomposites for electro-detection of nitrite ions: Effect of composite substrate

This work introduces an electrochemical sensor designed for detection of nitrite ions using multi walled carbon nanotubes bimetallic zeolitic imidazole frameworks (MWCNTs-Co/Zn ZIFs) and MXene-Co/Zn ZIFs modified carbon ceramic electrodes (CCE) through a one-step electrochemical process. The pHysiochemical characterizations of modified electrodes were investigated by using X-ray powder diffraction, Fourier transform infrared spectroscopy, scanning electron microscope, energy dispersive X-ray and electrochemical methods. Cyclic voltammetry and chronoamperometry techniques were used to assess the electrochemical performance of the modified electrodes toward oxidation and determination of nitrite ions. Both of the MWCNTs-Co/Zn ZIFs/CCE and MXene-Co/Zn ZIFs/CCE show high electrocatalytic activity for oxidation of nitrite ions in neutral media (pH = 7.0). Owing to the fascinating synergy between the intrinsic two-dimensional MXene and Co/Zn-ZIFs, the MXene-Co/Zn-ZIFs/CCE shows better electrocatalytic activity than the MWCNTs-Co/Zn ZIFs/CCE. The selected sensor, MXene-Co/Zn ZIFs/CCE, exhibits a linear response range from 2 to 500 μM, LOD (1.6 μM), LOQ (5.5 μM) and sensitivity (1.80180 μA mM −1 cm −2 ). Moreover, this sensor retains 96.77 % of its initial response after 25 days of storage at room temperature in the laboratory. Finally, the MXene-Co/Zn ZIFs/CCE was used for determination of nitrite ions in real samples with satisfactory results which suggests that the constructed sensor has high potential application in food samples analysis. • Nanocomposites were prepared by a one-step electrochemical process and characterized. • The MXene-Co/Zn ZIFs/GCE showed the highest electrocatalytic activity toward nitrite ions. • The MXene-Co/Zn ZIFs/GCE was used as a sensor for electrodetermination of nitrite ions. • The prepared sensor has excellent analytical performance in determination of nitrite ions. • Practical feasibility of sensor was verified by detecting of nitrite ions in real samples.

Authors

Institutions

Publication Details

Journal
Results in Chemistry
Published
2025-03-27
DOI
https://doi.org/10.1016/j.rechem.2025.102215
Citations
11
Primary Topic
MXene and MAX Phase Materials
Type
article
Field-Weighted Citation Impact
5.70

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Co/Zn ZIFs with MXene and MWCNTs nanocomposites for electro-detection of nitrite ions: Effect of composite substrate

Samaneh Makani, Rahim Mohammad‐Rezaei, Biuck Habibi
11 citations
Results in Chemistry
MXene and MAX Phase Materials
5.70
article

Co/Zn ZIFs with MXene and MWCNTs nanocomposites for electro-detection of nitrite ions: Effect of composite substrate

Samaneh Makani, Rahim Mohammad‐Rezaei, Biuck Habibi
article en
11 citations

Abstract

This work introduces an electrochemical sensor designed for detection of nitrite ions using multi walled carbon nanotubes bimetallic zeolitic imidazole frameworks (MWCNTs-Co/Zn ZIFs) and MXene-Co/Zn ZIFs modified carbon ceramic electrodes (CCE) through a one-step electrochemical process. The pHysiochemical characterizations of modified electrodes were investigated by using X-ray powder diffraction, Fourier transform infrared spectroscopy, scanning electron microscope, energy dispersive X-ray and electrochemical methods. Cyclic voltammetry and chronoamperometry techniques were used to assess the electrochemical performance of the modified electrodes toward oxidation and determination of nitrite ions. Both of the MWCNTs-Co/Zn ZIFs/CCE and MXene-Co/Zn ZIFs/CCE show high electrocatalytic activity for oxidation of nitrite ions in neutral media (pH = 7.0). Owing to the fascinating synergy between the intrinsic two-dimensional MXene and Co/Zn-ZIFs, the MXene-Co/Zn-ZIFs/CCE shows better electrocatalytic activity than the MWCNTs-Co/Zn ZIFs/CCE. The selected sensor, MXene-Co/Zn ZIFs/CCE, exhibits a linear response range from 2 to 500 μM, LOD (1.6 μM), LOQ (5.5 μM) and sensitivity (1.80180 μA mM −1 cm −2 ). Moreover, this sensor retains 96.77 % of its initial response after 25 days of storage at room temperature in the laboratory. Finally, the MXene-Co/Zn ZIFs/CCE was used for determination of nitrite ions in real samples with satisfactory results which suggests that the constructed sensor has high potential application in food samples analysis. • Nanocomposites were prepared by a one-step electrochemical process and characterized. • The MXene-Co/Zn ZIFs/GCE showed the highest electrocatalytic activity toward nitrite ions. • The MXene-Co/Zn ZIFs/GCE was used as a sensor for electrodetermination of nitrite ions. • The prepared sensor has excellent analytical performance in determination of nitrite ions. • Practical feasibility of sensor was verified by detecting of nitrite ions in real samples.

Results in ChemistryVol. 15
Azarbaijan Shahid Madani University (IR)
Azarbaijan Shahid Madani University
Openalex Percentile: Top 4%
MXene and MAX Phase Materials
5.70
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.