The effect of fuel concentration on intrinsic flame instabilities and flame acceleration in lean H2-CO-air mixtures

In large scale accident scenarios of nuclear power plants core meltdown and molten-core-concrete-interaction can occur. Large amounts of syngas mainly consisting of hydrogen (H 2 ) and carbon monoxide (CO) might be formed and mixed with the surrounding air, developing a potentially explosive mixture. The ignition of the flammable mixture might lead to flame acceleration and in worst cases to the destruction of the reactor building, causing the detachment of radioactive substances to the environment. To prevent future accidents, the understanding of flame accelerating conditions of syngas-air mixtures, in specific the understanding of the flame topology, must be improved. To the authors’ knowledge, insufficient data on flame topology investigating ignition and early stages of flame propagation in lean H 2 -CO-air mixtures is available. Therefore, in this study experiments are carried out to analyze the ignition and slow deflagration of a 50/50 H 2 /CO fuel mixture with fuel-to-air concentrations between 13.0 vol.-% - 29.5 vol.-%. A model calculating the flame acceleration in early stages of flame propagation is suggested. The GraVent explosion channel located at Technical University of Munich is used for the experiments in this study in its configuration of 1300 mm in length and a rectangular cross section of 300 × 60 mm. OH-PLIF measurements are used to determine flame front speed, flame acceleration and flame front length. Wrinkling factors are determined by the division of the wrinkled flame front length caused by intrinsic flame front instabilities and the smooth flame front length to quantify the influence of intrinsic flame front instabilities on early stages of flame acceleration. The optical experimental data contains the ignition of the gas mixtures as well as early stages of flame propagation. In conclusion, the results gathered in this study provide information on the topology of H 2 -CO-air flames under lean conditions enhancing the understanding of syngas flame acceleration and extending experimental data provided in former studies with relevance to large scale accident scenarios of nuclear power plants. • H 2 -CO-air explosions in loss of coolant accidents in nuclear power plants. • Investigation on laminar, premixed H 2 -CO-air combustion using OH-PLIF. • Measurements of the flame acceleration. • Determination of the flame front surface enlargement due to small-scale wrinkling using the wrinkling factor. • Equation for calculating the flame acceleration for 50/50 H 2 /CO fuel mixtures between 13 - 29.5 vol.-% fuel in air.

Authors

Institutions

Publication Details

Journal
Journal of Loss Prevention in the Process Industries
Published
2025-03-27
DOI
https://doi.org/10.1016/j.jlp.2025.105643
Citations
1
Primary Topic
Combustion and Detonation Processes
Type
article
Field-Weighted Citation Impact
4.99
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The effect of fuel concentration on intrinsic flame instabilities and flame acceleration in lean H2-CO-air mixtures

Agnes Jocher, Kajetan Planötscher
1 citations
Journal of Loss Prevention in the Process Industries
Combustion and Detonation Processes
4.99
article

The effect of fuel concentration on intrinsic flame instabilities and flame acceleration in lean H2-CO-air mixtures

Agnes Jocher, Kajetan Planötscher
article en
1 citations

Abstract

In large scale accident scenarios of nuclear power plants core meltdown and molten-core-concrete-interaction can occur. Large amounts of syngas mainly consisting of hydrogen (H 2 ) and carbon monoxide (CO) might be formed and mixed with the surrounding air, developing a potentially explosive mixture. The ignition of the flammable mixture might lead to flame acceleration and in worst cases to the destruction of the reactor building, causing the detachment of radioactive substances to the environment. To prevent future accidents, the understanding of flame accelerating conditions of syngas-air mixtures, in specific the understanding of the flame topology, must be improved. To the authors’ knowledge, insufficient data on flame topology investigating ignition and early stages of flame propagation in lean H 2 -CO-air mixtures is available. Therefore, in this study experiments are carried out to analyze the ignition and slow deflagration of a 50/50 H 2 /CO fuel mixture with fuel-to-air concentrations between 13.0 vol.-% - 29.5 vol.-%. A model calculating the flame acceleration in early stages of flame propagation is suggested. The GraVent explosion channel located at Technical University of Munich is used for the experiments in this study in its configuration of 1300 mm in length and a rectangular cross section of 300 × 60 mm. OH-PLIF measurements are used to determine flame front speed, flame acceleration and flame front length. Wrinkling factors are determined by the division of the wrinkled flame front length caused by intrinsic flame front instabilities and the smooth flame front length to quantify the influence of intrinsic flame front instabilities on early stages of flame acceleration. The optical experimental data contains the ignition of the gas mixtures as well as early stages of flame propagation. In conclusion, the results gathered in this study provide information on the topology of H 2 -CO-air flames under lean conditions enhancing the understanding of syngas flame acceleration and extending experimental data provided in former studies with relevance to large scale accident scenarios of nuclear power plants. • H 2 -CO-air explosions in loss of coolant accidents in nuclear power plants. • Investigation on laminar, premixed H 2 -CO-air combustion using OH-PLIF. • Measurements of the flame acceleration. • Determination of the flame front surface enlargement due to small-scale wrinkling using the wrinkling factor. • Equation for calculating the flame acceleration for 50/50 H 2 /CO fuel mixtures between 13 - 29.5 vol.-% fuel in air.

Journal of Loss Prevention in the Process IndustriesVol. 96
Technical University of Munich (DE)
Affordable and clean energy
Openalex Percentile: Top 7%
Combustion and Detonation Processes
4.99
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.