Fractional order ANFIS controllers for LFC in RES integrated three-area power system

Abstract The existing adaptive neuro-fuzzy inference system (ANFIS) for load frequency control in multi-area power systems has two inputs consisting of area control error (ACE) and its integer order derivative. A recently proposed ANFIS has added another input consisting of integer order integral of the ACE. In this paper, ANFIS controllers with fractional order derivative of the ACE and fractional order integral of the ACE, referred to as fractional order ANFIS (FO-ANFIS) controllers in this paper, are used instead to improve the performance of ANFIS controllers. The FO-ANFIS training dataset is obtained from the input ACE, its fractional order derivative and its fractional order integral of a cascaded fractional order PI-fractional order PID with derivative filters (FOPI-FOPIDN) tuned by a particle swarm optimization variant called adaptive dynamic inertia weight acceleration coefficient optimization algorithm. The controllers consisting of 2-input FO-ANFIS and 3-input FO-ANFIS, are tested on a three-area power system integrated with renewable energy sources. The results obtained are compared with those of their integer order ANFIS (IO-AFIS) counterparts and the FOPI-FOPIDN from which the training data was obtained using the overshoot, undershoot, settling time, steady-state error in the frequency and tie-line power responses as well as integral time absolute error values. Their real-world applicability is validated by incorporating communication time delay and governor dead band in one of the four experimental scenarios used for the evaluation. Robustness to power system parameter uncertainty is further assessed through parameter variation of ± 25%. From the results, the 3-input FO-ANFIS controller emerges as the best performing between the ANFIS controllers followed by the 2-input FO-ANFIS controller.

Authors

Institutions

Publication Details

Journal
Journal of Electrical Systems and Information Technology
Published
2025-03-26
DOI
https://doi.org/10.1186/s43067-025-00200-5
Citations
2
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
1.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fractional order ANFIS controllers for LFC in RES integrated three-area power system

Philip Yaw Okyere, Francis Boafo Effah, Yaw Opoku Mensah Sekyere
2 citations
Journal of Electrical Systems and Information Technology
Frequency Control in Power Systems
1.46
article

Fractional order ANFIS controllers for LFC in RES integrated three-area power system

Philip Yaw Okyere, Francis Boafo Effah, Yaw Opoku Mensah Sekyere
article en
2 citations

Abstract

Abstract The existing adaptive neuro-fuzzy inference system (ANFIS) for load frequency control in multi-area power systems has two inputs consisting of area control error (ACE) and its integer order derivative. A recently proposed ANFIS has added another input consisting of integer order integral of the ACE. In this paper, ANFIS controllers with fractional order derivative of the ACE and fractional order integral of the ACE, referred to as fractional order ANFIS (FO-ANFIS) controllers in this paper, are used instead to improve the performance of ANFIS controllers. The FO-ANFIS training dataset is obtained from the input ACE, its fractional order derivative and its fractional order integral of a cascaded fractional order PI-fractional order PID with derivative filters (FOPI-FOPIDN) tuned by a particle swarm optimization variant called adaptive dynamic inertia weight acceleration coefficient optimization algorithm. The controllers consisting of 2-input FO-ANFIS and 3-input FO-ANFIS, are tested on a three-area power system integrated with renewable energy sources. The results obtained are compared with those of their integer order ANFIS (IO-AFIS) counterparts and the FOPI-FOPIDN from which the training data was obtained using the overshoot, undershoot, settling time, steady-state error in the frequency and tie-line power responses as well as integral time absolute error values. Their real-world applicability is validated by incorporating communication time delay and governor dead band in one of the four experimental scenarios used for the evaluation. Robustness to power system parameter uncertainty is further assessed through parameter variation of ± 25%. From the results, the 3-input FO-ANFIS controller emerges as the best performing between the ANFIS controllers followed by the 2-input FO-ANFIS controller.

Journal of Electrical Systems and Information TechnologyVol. 12(1)
Kwame Nkrumah University of Science and Technology (GH)
Openalex Percentile: Top 19%
Frequency Control in Power Systems
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.