Validation of a Novel “Windshield Wiper” for Laparoscopes in Cadaver and Live Porcine Models

BackgroundDuring laparoscopic surgeries, laparoscopes are inserted through a trocar port into the body cavity, which is then insufflated with carbon dioxide. Laparoscope lens clarity frequently becomes compromised via condensation or smearing of blood and adipose. This problem is well-known in the field, yet a viable in vivo solution has yet to address the issue and be successfully clinically adopted.Research DesignA structured cadaveric study evaluated the cleaning performance and clinician satisfaction with a novel laparoscope lens cleaning device against 2 gold-standard lens cleaning products. The novel device was also tested in a live animal porcine model to assess cleaning performance in a warm body environment qualitatively. The validation in the porcine model did not have the same evaluation process and comparison with other lens clearing methods as the cadaveric experiment.ResultsCleaning events were timed individually and analyzed post hoc. Average times to clean scopes for the novel device, Clearify™, and Fred™ Anti-Fog solution were 5 ± 5, 16 ± 7, and 14 ± 6 seconds, respectively. In 100 cleaning events with the novel device, the laparoscope was removed from the body zero times, with an average of 2 ± 1.29 cleaning actuations per event. Clearify™ and Fred™ Anti-Fog were removed from the body 102 and 116 times, with an average number of cleaning actuations of 1.07 ± 0.26 and 1.19 ± 0.53 per event, respectively. In the live porcine model, the novel device consistently cleared all debris deposited on the lens, including fog, tissue, blood, and bile fluid.ConclusionThis study demonstrates the novel device's reduction in cleaning duration and scope removals compared to gold-standard technologies, suggesting a potential for improved workflow and reduced intra-operative interruptions.

Authors

Institutions

Publication Details

Journal
Surgical Innovation
Published
2025-03-25
DOI
https://doi.org/10.1177/15533506251329635
Primary Topic
Surgical Simulation and Training
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of a Novel “Windshield Wiper” for Laparoscopes in Cadaver and Live Porcine Models

Jawad Ali, Austin Fagerberg, Luis Fuentes, John Uecker et al.
Surgical Innovation
Surgical Simulation and Training
article

Validation of a Novel “Windshield Wiper” for Laparoscopes in Cadaver and Live Porcine Models

Jawad Ali, Austin Fagerberg, Luis Fuentes, John Uecker, Simin Golestani, Aaron A. Laviana, Etse-Oghena Y. Campbell, Christopher R. Idelson
article en

Abstract

BackgroundDuring laparoscopic surgeries, laparoscopes are inserted through a trocar port into the body cavity, which is then insufflated with carbon dioxide. Laparoscope lens clarity frequently becomes compromised via condensation or smearing of blood and adipose. This problem is well-known in the field, yet a viable in vivo solution has yet to address the issue and be successfully clinically adopted.Research DesignA structured cadaveric study evaluated the cleaning performance and clinician satisfaction with a novel laparoscope lens cleaning device against 2 gold-standard lens cleaning products. The novel device was also tested in a live animal porcine model to assess cleaning performance in a warm body environment qualitatively. The validation in the porcine model did not have the same evaluation process and comparison with other lens clearing methods as the cadaveric experiment.ResultsCleaning events were timed individually and analyzed post hoc. Average times to clean scopes for the novel device, Clearify™, and Fred™ Anti-Fog solution were 5 ± 5, 16 ± 7, and 14 ± 6 seconds, respectively. In 100 cleaning events with the novel device, the laparoscope was removed from the body zero times, with an average of 2 ± 1.29 cleaning actuations per event. Clearify™ and Fred™ Anti-Fog were removed from the body 102 and 116 times, with an average number of cleaning actuations of 1.07 ± 0.26 and 1.19 ± 0.53 per event, respectively. In the live porcine model, the novel device consistently cleared all debris deposited on the lens, including fog, tissue, blood, and bile fluid.ConclusionThis study demonstrates the novel device's reduction in cleaning duration and scope removals compared to gold-standard technologies, suggesting a potential for improved workflow and reduced intra-operative interruptions.

Surgical InnovationVol. 32(4)
The University of Texas at Austin (US), The University of Texas Health Science Center at Houston (US)
National Institute of Biomedical Imaging and Bioengineering
Industry, innovation and infrastructure
Openalex Percentile: Top 90%
Surgical Simulation and Training
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.