Evaluating Arrhythmia Alerts from Smartwatches in Asymptomatic Emergency Patients

Smartwatches equipped with photoplethysmography (PPG) sensors are increasingly used for arrhythmia detection, yet their diagnostic accuracy in asymptomatic patients presenting to the emergency department (ED) remains underexplored. This study aimed to evaluate the performance of PPG-equipped smartwatches in detecting arrhythmias among asymptomatic patients and compare smartwatch-generated alerts with standard 12-lead electrocardiograms (ECG). This retrospective observational study included 523 asymptomatic patients who presented to a tertiary care ED over a one-year period with smartwatch-generated arrhythmia alerts. All patients underwent a standard 12-lead ECG upon arrival. Arrhythmias were categorized as atrial fibrillation (AF), sinus bradycardia, bundle branch block (BBB), or ischemic changes. Diagnostic metrics including sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and overall accuracy were calculated for each condition. Misclassification rates were analyzed to assess smartwatch limitations. Of the patients, 35.27% had abnormalities detected by ECG, including AF (18.2%), sinus bradycardia (10.9%), BBB (17.5%), and ischemic changes (25.5%). For AF, smartwatches demonstrated a sensitivity of 53.85%, specificity of 69.06%, PPV of 28.87%, and NPV of 86.52%, with an overall accuracy of 66.18%. Detection rates were lower for sinus bradycardia (sensitivity 30.36%) and ischemic changes (sensitivity 4.88%). Misclassification rates were particularly high for ischemic changes (95.7%), sinus bradycardia (70%), and BBB (75%). While smartwatches exhibit moderate utility for AF detection, their limited accuracy for other arrhythmias underscores the need for algorithmic improvements. Despite these limitations, smartwatches may serve as supplementary tools to encourage early medical attention in asymptomatic patients.

Authors

Institutions

Publication Details

Journal
Gümüşhane Üniversitesi Sağlık Bilimleri Dergisi
Published
2025-03-23
DOI
https://doi.org/10.37989/gumussagbil.1616151
Citations
1
Primary Topic
Healthcare Technology and Patient Monitoring
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating Arrhythmia Alerts from Smartwatches in Asymptomatic Emergency Patients

Ömerul Faruk Aydın, Gülbin Aydoğdu Umaç
1 citations
Gümüşhane Üniversitesi Sağlık Bilimleri Dergisi
Healthcare Technology and Patient Monitoring
2.01
article

Evaluating Arrhythmia Alerts from Smartwatches in Asymptomatic Emergency Patients

Ömerul Faruk Aydın, Gülbin Aydoğdu Umaç
article en
1 citations

Abstract

Smartwatches equipped with photoplethysmography (PPG) sensors are increasingly used for arrhythmia detection, yet their diagnostic accuracy in asymptomatic patients presenting to the emergency department (ED) remains underexplored. This study aimed to evaluate the performance of PPG-equipped smartwatches in detecting arrhythmias among asymptomatic patients and compare smartwatch-generated alerts with standard 12-lead electrocardiograms (ECG). This retrospective observational study included 523 asymptomatic patients who presented to a tertiary care ED over a one-year period with smartwatch-generated arrhythmia alerts. All patients underwent a standard 12-lead ECG upon arrival. Arrhythmias were categorized as atrial fibrillation (AF), sinus bradycardia, bundle branch block (BBB), or ischemic changes. Diagnostic metrics including sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and overall accuracy were calculated for each condition. Misclassification rates were analyzed to assess smartwatch limitations. Of the patients, 35.27% had abnormalities detected by ECG, including AF (18.2%), sinus bradycardia (10.9%), BBB (17.5%), and ischemic changes (25.5%). For AF, smartwatches demonstrated a sensitivity of 53.85%, specificity of 69.06%, PPV of 28.87%, and NPV of 86.52%, with an overall accuracy of 66.18%. Detection rates were lower for sinus bradycardia (sensitivity 30.36%) and ischemic changes (sensitivity 4.88%). Misclassification rates were particularly high for ischemic changes (95.7%), sinus bradycardia (70%), and BBB (75%). While smartwatches exhibit moderate utility for AF detection, their limited accuracy for other arrhythmias underscores the need for algorithmic improvements. Despite these limitations, smartwatches may serve as supplementary tools to encourage early medical attention in asymptomatic patients.

Gümüşhane Üniversitesi Sağlık Bilimleri DergisiVol. 14(1)
Istanbul Yeni Yüzyıl University (TR), Izmir Tepecik Eğitim ve Araştırma Hastanesi (TR), İzmir Şehir Hastanesi (TR)
Openalex Percentile: Top 18%
Healthcare Technology and Patient Monitoring
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.