Development and characterization of a Dextran/CaCl<sub>2</sub>-based blood-mimicking fluid: a comparative study of rheological and mechanical properties in artificial erythrocyte suspensions

The development of accurate blood-mimicking fluids (BMFs) is essential for <i>in vitro</i> studies of blood contacting medical devices. Experimental data typically relies on single-phase glycerin/water solutions as substitutes to visualize simplified blood flow. These models are accurate only at high shear rates, limiting their applicability at lower shear rates. In this study, we investigated three potential BMFs, each composed of poly(sodium acrylate-<i>co</i>-acrylamide) hydrogel microparticles (beads) as artificial erythrocytes. Microbeads were produced using microfluidic systems (MFS) and were suspended in three plasma-like solutions: 10% and 50% (v/v) glycerol/water solutions and a Dextran40/CaCl<sub>2</sub> solution. The BMFs were evaluated for their rheological and mechanical properties, including particle elasticity, sedimentation behavior, and shear flow analysis, to assess their suitability for mimicking blood. Rheometric measurements were performed at room temperature using a plate-plate configuration, measuring viscosity and shear stress for shear rates of 5-500 s<sup>-1</sup>. Atomic force microscopy (AFM) measurements were conducted to assess their mechanical response. The Dextran40/CaCl<sub>2</sub>-based BMF was identified as the most promising, demonstrating rheological and mechanical properties that closely align with those of human blood. This research offers a refined approach to developing blood analogs that better simulate the mechanical response and flow characteristics of blood for the validation and development of blood contacting medical devices.

Authors

Institutions

Publication Details

Journal
Soft Matter
Published
2025-01-01
DOI
https://doi.org/10.1039/d4sm01510j
Citations
4
Primary Topic
Blood properties and coagulation
Type
article
Field-Weighted Citation Impact
6.07

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and characterization of a Dextran/CaCl2-based blood-mimicking fluid: a comparative study of rheological and mechanical properties in artificial erythrocyte suspensions

Birgit Glasmacher, Marc Mueller, Gesine Hentschel, Katharina Doll‐Nikutta et al.
4 citations
Soft Matter
Blood properties and coagulation
6.07
article

Development and characterization of a Dextran/CaCl2-based blood-mimicking fluid: a comparative study of rheological and mechanical properties in artificial erythrocyte suspensions

Birgit Glasmacher, Marc Mueller, Gesine Hentschel, Katharina Doll‐Nikutta, Philipp Berg
article en
4 citations

Abstract

The development of accurate blood-mimicking fluids (BMFs) is essential for <i>in vitro</i> studies of blood contacting medical devices. Experimental data typically relies on single-phase glycerin/water solutions as substitutes to visualize simplified blood flow. These models are accurate only at high shear rates, limiting their applicability at lower shear rates. In this study, we investigated three potential BMFs, each composed of poly(sodium acrylate-<i>co</i>-acrylamide) hydrogel microparticles (beads) as artificial erythrocytes. Microbeads were produced using microfluidic systems (MFS) and were suspended in three plasma-like solutions: 10% and 50% (v/v) glycerol/water solutions and a Dextran40/CaCl<sub>2</sub> solution. The BMFs were evaluated for their rheological and mechanical properties, including particle elasticity, sedimentation behavior, and shear flow analysis, to assess their suitability for mimicking blood. Rheometric measurements were performed at room temperature using a plate-plate configuration, measuring viscosity and shear stress for shear rates of 5-500 s<sup>-1</sup>. Atomic force microscopy (AFM) measurements were conducted to assess their mechanical response. The Dextran40/CaCl<sub>2</sub>-based BMF was identified as the most promising, demonstrating rheological and mechanical properties that closely align with those of human blood. This research offers a refined approach to developing blood analogs that better simulate the mechanical response and flow characteristics of blood for the validation and development of blood contacting medical devices.

Soft MatterVol. 21(16)
Leibniz University Hannover (DE), Medizinische Hochschule Hannover (DE), University Hospital Magdeburg (DE)
Bundesministerium für Bildung und Forschung
Openalex Percentile: Top 4%
Blood properties and coagulation
6.07
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.