Measurement of Anti-TNF Biologics in Serum Samples of Pediatric Patients: Comparison of Enzyme-Linked Immunosorbent Assay (ELISA) with a Rapid and Automated Fluorescence-Based Lateral Flow Immunoassay

<b>Background</b>: Therapeutic drug monitoring (TDM) of infliximab (IFX) and adalimumab (ADL) mainly relies on the use of enzyme-linked immunosorbent assays (ELISA). More recently, rapid assays have been developed and validated to reduce turnaround time (TAT). Here, we compared IFX and ADL concentrations measured with both ELISA and a new fluorescence-based lateral flow immunoassay (AFIAS). <b>Methods</b>: In serum samples from pediatric patients, IFX and ADL drug levels, and total anti-IFX antibodies were measured using clinically validated ELISA kits (Immundiagnostik AG). Samples were further analyzed using a new rapid assay (AFIAS, Boditech Med Inc.) to measure drug levels and total anti-IFX antibodies. <b>Results</b>: Spearman's correlation coefficients (rho) were 0.98 [95% confidence interval (CI) 0.97 to 0.99] for IFX (<i>p</i> < 0.001) and 0.83 (95% CI 0.72 to 0.90) for ADL (<i>p</i> < 0.001). Calculated % bias was -14.09 (95% Limits of agreement, LoA, -52.83 to 24.66) for IFX and 15.79 (LoA -37.14 to 68.73) for ADL. For the evaluation of total anti-IFX antibodies, we did not collect sufficient data to establish a statistically significant correlation between AFIAS and ELISA. The inter-rater agreement showed a "substantial" and a "moderate" agreement for IFX and ADL, respectively. <b>Conclusions</b>: Our results show that the AFIAS assay has an accuracy and analytical performance comparable to that of the ELISA method used for TDM of IFX and ADL. Therefore, the introduction of this device into routine clinical practice could provide results more quickly and with similar accuracy as ELISA, allowing clinicians to rapidly formulate clinical decisions.

Authors

Institutions

Publication Details

Journal
Pharmaceutics
Published
2025-03-26
DOI
https://doi.org/10.3390/pharmaceutics17040421
Primary Topic
Immunodeficiency and Autoimmune Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement of Anti-TNF Biologics in Serum Samples of Pediatric Patients: Comparison of Enzyme-Linked Immunosorbent Assay (ELISA) with a Rapid and Automated Fluorescence-Based Lateral Flow Immunoassay

Simona Faraci, Alessia Vitale, A. Mancini, Silvia Magni‐Manzoni et al.
Pharmaceutics
Immunodeficiency and Autoimmune Disorders
article

Measurement of Anti-TNF Biologics in Serum Samples of Pediatric Patients: Comparison of Enzyme-Linked Immunosorbent Assay (ELISA) with a Rapid and Automated Fluorescence-Based Lateral Flow Immunoassay

Simona Faraci, Alessia Vitale, A. Mancini, Silvia Magni‐Manzoni, F. Bracci, Sara Cairoli, Giulia Angelino, Chiara Rossi, G Tarantino, Raffaele Simeoli, Erminia Romeo, D. Knafelz, Bianca Maria Goffredo, Carlo Dionisi‐Vici, Paola De Angelis
article en

Abstract

<b>Background</b>: Therapeutic drug monitoring (TDM) of infliximab (IFX) and adalimumab (ADL) mainly relies on the use of enzyme-linked immunosorbent assays (ELISA). More recently, rapid assays have been developed and validated to reduce turnaround time (TAT). Here, we compared IFX and ADL concentrations measured with both ELISA and a new fluorescence-based lateral flow immunoassay (AFIAS). <b>Methods</b>: In serum samples from pediatric patients, IFX and ADL drug levels, and total anti-IFX antibodies were measured using clinically validated ELISA kits (Immundiagnostik AG). Samples were further analyzed using a new rapid assay (AFIAS, Boditech Med Inc.) to measure drug levels and total anti-IFX antibodies. <b>Results</b>: Spearman's correlation coefficients (rho) were 0.98 [95% confidence interval (CI) 0.97 to 0.99] for IFX (<i>p</i> < 0.001) and 0.83 (95% CI 0.72 to 0.90) for ADL (<i>p</i> < 0.001). Calculated % bias was -14.09 (95% Limits of agreement, LoA, -52.83 to 24.66) for IFX and 15.79 (LoA -37.14 to 68.73) for ADL. For the evaluation of total anti-IFX antibodies, we did not collect sufficient data to establish a statistically significant correlation between AFIAS and ELISA. The inter-rater agreement showed a "substantial" and a "moderate" agreement for IFX and ADL, respectively. <b>Conclusions</b>: Our results show that the AFIAS assay has an accuracy and analytical performance comparable to that of the ELISA method used for TDM of IFX and ADL. Therefore, the introduction of this device into routine clinical practice could provide results more quickly and with similar accuracy as ELISA, allowing clinicians to rapidly formulate clinical decisions.

PharmaceuticsVol. 17(4)
Bambino Gesù Children's Hospital (IT), Istituti di Ricovero e Cura a Carattere Scientifico (IT)
Good health and well-being
Openalex Percentile: Top 94%
Immunodeficiency and Autoimmune Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.