Investigation of the Behavior of RC Elevated Water Tanks According to Turkish Earthquake Codes

Water tanks are critical structures that must be used without damage after an earthquake. Due to their vital importance, these structures are required to perform well under the influence of major earthquakes. In this study, the behavior of the RC elevated water tanks under earthquake effects was investigated. The water tank with a volume of 75 m3, which is widely applied as a type project, was examined according to the calculation principles of the 1968, 1975, 1998, 2007, and 2018 earthquake codes. The analysis of the structure designed in the SAP2000 program was carried out according to the equivalent linear method. When the analysis results were compared according to the earthquake codes considered, it was concluded that the structure showed better performance as the design criteria and calculation principles were improved from the 1968 earthquake code to the 2018 earthquake code. The comparative analysis results obtained from the study were evaluated specifically for an RC elevated water tank that was heavily damaged in the 6 February 2023 Kahramanmaraş earthquakes.

Authors

Institutions

Publication Details

Journal
Bitlis Eren Üniversitesi Fen Bilimleri Dergisi
Published
2025-03-26
DOI
https://doi.org/10.17798/bitlisfen.1592499
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of the Behavior of RC Elevated Water Tanks According to Turkish Earthquake Codes

Fatma ÜLKER PEKER
Bitlis Eren Üniversitesi Fen Bilimleri Dergisi
Seismic Performance and Analysis
article

Investigation of the Behavior of RC Elevated Water Tanks According to Turkish Earthquake Codes

Fatma ÜLKER PEKER
article en

Abstract

Water tanks are critical structures that must be used without damage after an earthquake. Due to their vital importance, these structures are required to perform well under the influence of major earthquakes. In this study, the behavior of the RC elevated water tanks under earthquake effects was investigated. The water tank with a volume of 75 m3, which is widely applied as a type project, was examined according to the calculation principles of the 1968, 1975, 1998, 2007, and 2018 earthquake codes. The analysis of the structure designed in the SAP2000 program was carried out according to the equivalent linear method. When the analysis results were compared according to the earthquake codes considered, it was concluded that the structure showed better performance as the design criteria and calculation principles were improved from the 1968 earthquake code to the 2018 earthquake code. The comparative analysis results obtained from the study were evaluated specifically for an RC elevated water tank that was heavily damaged in the 6 February 2023 Kahramanmaraş earthquakes.

Bitlis Eren Üniversitesi Fen Bilimleri DergisiVol. 14(1)
Malatya Turgut Özal Üniversitesi (TR)
Openalex Percentile: Top 94%
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Investigation of the Behavior of RC Elevated Water Tanks According to Turkish Earthquake Codes — Fatma ÜLKER PEKER · Bitlis Eren Üniversitesi Fen Bilimleri Dergisi (2025) | TGRS Research Map | TGRS