Cyber Recovery From Dynamic Load Altering Attacks: Linking Electricity, Transportation, and Cyber Networks

The dynamic load alternating attack (DLAA) that manipulates the load demands in power grid by compromising internet of things (IoT) home appliances has posed significant threats to the grid’s stable and safe operation. Current effort is mainly devoted to the investigation of detecting and mitigating DLAAs, while, for a holistic cyber-resiliency-enhancement process, the last but not least cyber recovery from DLAAs (CRDA) has not been paid enough attention yet. Considering the interconnection among electricity, transportation, and cyber networks, this paper presents the first exploration of the CRDA, where two essential sub-tasks are formulated: i) Optimal design of repair crew routes to remove installed malware and ii) Robust adjustment of system operation to eliminate the mitigation costs with stability guarantee. Towards this end, linear stability constraints are established by utilising a sensitivity-based eigenvalue estimation method, where the eigenvalue sensitivity information is appropriately ordered and strategically selected to guarantee the estimation accuracy. Moreover, to assure the CRDA solution’s robustness to the adversary’s follow-up movement, the worst-case attack strategies in all attack scenarios during the recovery process are integrated. A mixed-integer linear programming (MILP) problem is subsequently developed for the CRDA with the primary objective to restore the secure but cost-inefficient mitigation operation mode to the cost-efficient one and secondarily to repair compromised IoT home appliances. Case studies are performed in IEEE power system cases to validate the eigenvalue estimation’s accuracy, the CRDA solution’s effectiveness and robustness, as well as the proposed CRDA’s extensibility.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Information Forensics and Security
Published
2025-01-01
DOI
https://doi.org/10.1109/tifs.2025.3553079
Citations
3
Primary Topic
Smart Grid Security and Resilience
Type
article
Field-Weighted Citation Impact
3.64

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cyber Recovery From Dynamic Load Altering Attacks: Linking Electricity, Transportation, and Cyber Networks

Zhongda Chu, Mengxiang Liu, Fei Teng
3 citations
IEEE Transactions on Information Forensics and Security
Smart Grid Security and Resilience
3.64
article

Cyber Recovery From Dynamic Load Altering Attacks: Linking Electricity, Transportation, and Cyber Networks

Zhongda Chu, Mengxiang Liu, Fei Teng
article en
3 citations

Abstract

The dynamic load alternating attack (DLAA) that manipulates the load demands in power grid by compromising internet of things (IoT) home appliances has posed significant threats to the grid’s stable and safe operation. Current effort is mainly devoted to the investigation of detecting and mitigating DLAAs, while, for a holistic cyber-resiliency-enhancement process, the last but not least cyber recovery from DLAAs (CRDA) has not been paid enough attention yet. Considering the interconnection among electricity, transportation, and cyber networks, this paper presents the first exploration of the CRDA, where two essential sub-tasks are formulated: i) Optimal design of repair crew routes to remove installed malware and ii) Robust adjustment of system operation to eliminate the mitigation costs with stability guarantee. Towards this end, linear stability constraints are established by utilising a sensitivity-based eigenvalue estimation method, where the eigenvalue sensitivity information is appropriately ordered and strategically selected to guarantee the estimation accuracy. Moreover, to assure the CRDA solution’s robustness to the adversary’s follow-up movement, the worst-case attack strategies in all attack scenarios during the recovery process are integrated. A mixed-integer linear programming (MILP) problem is subsequently developed for the CRDA with the primary objective to restore the secure but cost-inefficient mitigation operation mode to the cost-efficient one and secondarily to repair compromised IoT home appliances. Case studies are performed in IEEE power system cases to validate the eigenvalue estimation’s accuracy, the CRDA solution’s effectiveness and robustness, as well as the proposed CRDA’s extensibility.

IEEE Transactions on Information Forensics and SecurityVol. 20
Imperial College London (GB)
Engineering and Physical Sciences Research Council
Affordable and clean energy
Openalex Percentile: Top 8%
Smart Grid Security and Resilience
3.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Cyber Recovery From Dynamic Load Altering Attacks: Linking Electricity, Transportation, and Cyber Networks — Zhongda Chu, Mengxiang Liu, et al. · IEEE Transactions on Information Forensics and Security (2025) | TGRS Research Map | TGRS