Controlled Overvoltage DC Testing as a Diagnostic Tool for Low-Voltage Three-Phase Motors: A Case Study

Procedures for continuous high-voltage testing for stators rated at 2.3kV or higher are outlined in IEEE Std 95; however, there is no equivalent standard for testing low-voltage machines, especially for field testing. Nevertheless, multiple maintenance departments implement controlled overvoltage DC tests as a tool to detect defects in the groundwall insulation system of low-voltage motors and to evaluate the effects of various aging mechanisms that occur during normal operation. This article presents a case study demonstrating that, for low-voltage motors, the controlled overvoltage DC test is an excellent tool for detecting insulation defects that will inevitably lead to ground faults.

Authors

Publication Details

Published
2024-11-27
DOI
https://doi.org/10.1109/concapan63470.2024.10933831
Primary Topic
Magnetic Properties and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Controlled Overvoltage DC Testing as a Diagnostic Tool for Low-Voltage Three-Phase Motors: A Case Study

G. Gómez
Magnetic Properties and Applications
article

Controlled Overvoltage DC Testing as a Diagnostic Tool for Low-Voltage Three-Phase Motors: A Case Study

G. Gómez
article en

Abstract

Procedures for continuous high-voltage testing for stators rated at 2.3kV or higher are outlined in IEEE Std 95; however, there is no equivalent standard for testing low-voltage machines, especially for field testing. Nevertheless, multiple maintenance departments implement controlled overvoltage DC tests as a tool to detect defects in the groundwall insulation system of low-voltage motors and to evaluate the effects of various aging mechanisms that occur during normal operation. This article presents a case study demonstrating that, for low-voltage motors, the controlled overvoltage DC test is an excellent tool for detecting insulation defects that will inevitably lead to ground faults.

Affordable and clean energy
Openalex Percentile: Top 84%
Magnetic Properties and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Controlled Overvoltage DC Testing as a Diagnostic Tool for Low-Voltage Three-Phase Motors: A Case Study — G. Gómez · (2024) | TGRS Research Map | TGRS