A new paradigm for Light-addressable potentiometric sensor detection based on Gaussian fitting

Light-addressable potentiometric sensor (LAPS) is a low-cost and versatile semiconductor field-effect pH sensor. The measurement of pH by traditional LPAS usually adopts the way of normalizing the V-I characteristic curve, which needs to obtain the data of the whole V-I characteristic curve, resulting in slow measurement speed and long time. To address this problem, a new $\mathbf{p H}$ measurement method is proposed in this paper, which integrally considers the nonlinear error in the linear region by fitting a Gaussian function to the local linear region of the V-I characteristic curve, and the measurement results are directly obtained from the parameters of the fitted function. The experimental results show that the sensitivity and repetition rate of the new detection method can be comparable with that of the V I characteristic curve measurement method, and the linearity is improved by 0.81%, which helps to improve the measurement efficiency and realize the rapid measurement of pH.

Authors

Institutions

Publication Details

Published
2024-12-20
DOI
https://doi.org/10.1109/aiim64537.2024.10934359
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A new paradigm for Light-addressable potentiometric sensor detection based on Gaussian fitting

Jie Tan, Xin Cao, Zigeng Huang, Bing Sun
Advanced Chemical Sensor Technologies
article

A new paradigm for Light-addressable potentiometric sensor detection based on Gaussian fitting

Jie Tan, Xin Cao, Zigeng Huang, Bing Sun
article en

Abstract

Light-addressable potentiometric sensor (LAPS) is a low-cost and versatile semiconductor field-effect pH sensor. The measurement of pH by traditional LPAS usually adopts the way of normalizing the V-I characteristic curve, which needs to obtain the data of the whole V-I characteristic curve, resulting in slow measurement speed and long time. To address this problem, a new $\mathbf{p H}$ measurement method is proposed in this paper, which integrally considers the nonlinear error in the linear region by fitting a Gaussian function to the local linear region of the V-I characteristic curve, and the measurement results are directly obtained from the parameters of the fitted function. The experimental results show that the sensitivity and repetition rate of the new detection method can be comparable with that of the V I characteristic curve measurement method, and the linearity is improved by 0.81%, which helps to improve the measurement efficiency and realize the rapid measurement of pH.

Xihua University (CN)
Affordable and clean energy
Openalex Percentile: Top 75%
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.