Unsupervised Test-Time Adaptation for Hepatic Steatosis Grading Using Ultrasound B-Mode Images

Ultrasound (US) is considered a key modality for the clinical assessment of hepatic steatosis (i.e., fatty liver) due to its noninvasiveness and availability. Deep learning methods have attracted considerable interest in this field, as they are capable of learning patterns in a collection of images and achieve clinically comparable levels of accuracy in steatosis grading. However, variations in patient populations, acquisition protocols, equipment, and operator expertise across clinical sites can introduce domain shifts that reduce model performance when applied outside the original training setting. In response, unsupervised domain adaptation techniques are being investigated to address these shifts, allowing models to generalize more effectively across diverse clinical environments. In this work, we propose a test-time batch normalization (TTN) technique designed to handle domain shift, especially for changes in label distribution, by adapting selected features of batch normalization (BatchNorm) layers in a trained convolutional neural network model. This approach operates in an unsupervised manner, allowing robust adaptation to new distributions without access to label data. The method was evaluated on two abdominal US datasets collected at different institutions, assessing its capability in mitigating domain shift for hepatic steatosis classification. The proposed method reduced the mean absolute error in steatosis grading by 37% and improved the area under the receiver operating characteristic curves (AUC) for steatosis detection from 0.78 to 0.97, compared to nonadapted models. These findings demonstrate the potential of the proposed method to address domain shift in US-based hepatic steatosis diagnosis, minimizing risks associated with deploying trained models in various clinical settings.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Published
2025-03-27
DOI
https://doi.org/10.1109/tuffc.2025.3555180
Citations
5
Primary Topic
Liver Disease Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
6.77
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Unsupervised Test-Time Adaptation for Hepatic Steatosis Grading Using Ultrasound B-Mode Images

Guy Wolf, Pedro Vianna, Eugene Belilovsky, Guy Cloutier et al.
5 citations
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Liver Disease Diagnosis and Treatment
6.77
article

Unsupervised Test-Time Adaptation for Hepatic Steatosis Grading Using Ultrasound B-Mode Images

Guy Wolf, Pedro Vianna, Eugene Belilovsky, Guy Cloutier, Muawiz Chaudhary, An Tang, Michael Eickenberg, Paria Mehrbod
article en
5 citations

Abstract

Ultrasound (US) is considered a key modality for the clinical assessment of hepatic steatosis (i.e., fatty liver) due to its noninvasiveness and availability. Deep learning methods have attracted considerable interest in this field, as they are capable of learning patterns in a collection of images and achieve clinically comparable levels of accuracy in steatosis grading. However, variations in patient populations, acquisition protocols, equipment, and operator expertise across clinical sites can introduce domain shifts that reduce model performance when applied outside the original training setting. In response, unsupervised domain adaptation techniques are being investigated to address these shifts, allowing models to generalize more effectively across diverse clinical environments. In this work, we propose a test-time batch normalization (TTN) technique designed to handle domain shift, especially for changes in label distribution, by adapting selected features of batch normalization (BatchNorm) layers in a trained convolutional neural network model. This approach operates in an unsupervised manner, allowing robust adaptation to new distributions without access to label data. The method was evaluated on two abdominal US datasets collected at different institutions, assessing its capability in mitigating domain shift for hepatic steatosis classification. The proposed method reduced the mean absolute error in steatosis grading by 37% and improved the area under the receiver operating characteristic curves (AUC) for steatosis detection from 0.78 to 0.97, compared to nonadapted models. These findings demonstrate the potential of the proposed method to address domain shift in US-based hepatic steatosis diagnosis, minimizing risks associated with deploying trained models in various clinical settings.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency ControlVol. 72(5)
Flatiron Health (United States) (US), Mila - Quebec Artificial Intelligence Institute (CA), Flatiron Institute (US), Université de Montréal (CA)
Zero hunger
Openalex Percentile: Top 3%
Liver Disease Diagnosis and Treatment
6.77
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.