A physio-chemical mathematical model of the effects of O2 and CO2 diffusion between the blood and gas phases of venous blood sampled in vacuum tubes

Measurement of blood acid-base status is usually performed using standard blood gas syringes. This contrasts with venous blood for other purposes which are usually sampled in vacuum tubes which include a quantity of air. This study reports changes in blood sampled from normal participants over 90 min in standard blood gas syringes, and in vacuum tubes designed for blood gas sampling. It proposes a mathematical model based on physio-chemical processes to simulate changes occurring in the vacuum tubes due to contamination with air. Venous blood samples were taken from 20 normal participants, into standard blood gas syringes and analysed at baseline and 90 min; and 2 ml and 4 ml vacuum tubes analysed after 20 and 90 min. A mathematical model was proposed describing diffusion of O<sub>2</sub> and CO<sub>2</sub> between blood and gas phases of the vacuum tubes, and used to simulate corresponding measured values of plasma pH, pCO<sub>2</sub>, pO<sub>2</sub>, glucose, and lactate. Simulated and measured values were compared with Bland-Altman and correlation analysis. Differences between measured and model simulated values were (bias ± SD): pH -0.01 ± 0.01, pCO<sub>2</sub> 0.03 ± 0.17 kPa, pO<sub>2</sub> 0.88 ± 1.73 kPa, glucose -0.01 ± 0.11 mmol/l and lactate 0.06 ± 0.18 mmol/l. All linear correlations between measured and simulated values had R<sup>2</sup> > 0.90. This paper illustrates that the effects of sampling in vacuum tubes can be accurately simulated with a mathematical model of physio-chemistry. While further evaluation is necessary, this may indicate a role for this model in the use of vacuum tubes for routine acid-base and oxygenation analysis.

Authors

Institutions

Publication Details

Journal
Clinica Chimica Acta
Published
2025-03-26
DOI
https://doi.org/10.1016/j.cca.2025.120270
Citations
1
Primary Topic
Renal function and acid-base balance
Type
article
Field-Weighted Citation Impact
1.43

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A physio-chemical mathematical model of the effects of O2 and CO2 diffusion between the blood and gas phases of venous blood sampled in vacuum tubes

Stephen Edward Rees, Lisha Shastri, Lars Pilegaard Thomsen, Søren Risom Kristensen et al.
1 citations
Clinica Chimica Acta
Renal function and acid-base balance
1.43
article

A physio-chemical mathematical model of the effects of O2 and CO2 diffusion between the blood and gas phases of venous blood sampled in vacuum tubes

Stephen Edward Rees, Lisha Shastri, Lars Pilegaard Thomsen, Søren Risom Kristensen, Jette Nybo, Bahareh Nevirian
article en
1 citations

Abstract

Measurement of blood acid-base status is usually performed using standard blood gas syringes. This contrasts with venous blood for other purposes which are usually sampled in vacuum tubes which include a quantity of air. This study reports changes in blood sampled from normal participants over 90 min in standard blood gas syringes, and in vacuum tubes designed for blood gas sampling. It proposes a mathematical model based on physio-chemical processes to simulate changes occurring in the vacuum tubes due to contamination with air. Venous blood samples were taken from 20 normal participants, into standard blood gas syringes and analysed at baseline and 90 min; and 2 ml and 4 ml vacuum tubes analysed after 20 and 90 min. A mathematical model was proposed describing diffusion of O<sub>2</sub> and CO<sub>2</sub> between blood and gas phases of the vacuum tubes, and used to simulate corresponding measured values of plasma pH, pCO<sub>2</sub>, pO<sub>2</sub>, glucose, and lactate. Simulated and measured values were compared with Bland-Altman and correlation analysis. Differences between measured and model simulated values were (bias ± SD): pH -0.01 ± 0.01, pCO<sub>2</sub> 0.03 ± 0.17 kPa, pO<sub>2</sub> 0.88 ± 1.73 kPa, glucose -0.01 ± 0.11 mmol/l and lactate 0.06 ± 0.18 mmol/l. All linear correlations between measured and simulated values had R<sup>2</sup> > 0.90. This paper illustrates that the effects of sampling in vacuum tubes can be accurately simulated with a mathematical model of physio-chemistry. While further evaluation is necessary, this may indicate a role for this model in the use of vacuum tubes for routine acid-base and oxygenation analysis.

Clinica Chimica ActaVol. 572
Aalborg University Hospital (DK), Aalborg University (DK)
Roche
Openalex Percentile: Top 22%
Renal function and acid-base balance
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.