Magnetic Field Sensing With Magnetic Shape Memory Alloy and Fiber Bragg Grating on Silica and Polymer Optical Fibers

Optical fiber magnetic field sensors based on magnetostrictive materials have attracted significant interest. However, most existing sensors utilizing optical fibers and magnetostrictive materials have a limited measurement range up to 200 mT, posing a challenge for applications requiring the detection of strong magnetic fields, such as in maglev train systems. In this study, we introduce two magnetic field sensors: one based on a magnetic shape memory alloy-silica fiber Bragg grating (MSMA-SFBG) and the other on an MSMA-polymeric fiber Bragg grating (MSMA-PFBG). These sensors couple magnetic field-induced strain in the MSMA transducer with fiber Bragg gratings (FBGs) inscribed in the silica optical fiber and the polymer optical fiber, respectively. We evaluated the performance of these sensors in terms of sensitivity, measurement range, and saturation magnetic field. The MSMA-SFBG sensor exhibited a linear response with a sensitivity of approximately 2 pm/mT over the magnetic field range from 250 to 550 mT. The MSMA-PFBG sensor demonstrated a sensitivity of 46.02 pm/mT at 400 mT, outperforming Terfenol-D-based magnetic field sensors by about four times in sensitivity. By applying dc bias fields up to 268 mT, the sensitivity of the MSMA-SFBG sensor decreased from 2.01 to 0.56 pm/mT, while the linear measurement range expanded from 250–550 to 50–550 mT. Conversely, the sensitivity of the MSMA-PFBG sensor increased from 2.30 to 18.68 pm/mT at weak magnetic field of 150 mT, although both the measurement range and the saturation magnetic field decreased. These findings suggest that the two proposed MSMA-based magnetic field sensors complement one and other, are well-suited for applications requiring extensive range, and high-sensitivity magnetic field measurements.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3554890
Citations
3
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
2.19

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Magnetic Field Sensing With Magnetic Shape Memory Alloy and Fiber Bragg Grating on Silica and Polymer Optical Fibers

Hwa‐Yaw Tam, Jingxian Cui, Linyue Lu, Dinusha Dilhan Nawarathne
3 citations
IEEE Transactions on Instrumentation and Measurement
Advanced Fiber Optic Sensors
2.19
article

Magnetic Field Sensing With Magnetic Shape Memory Alloy and Fiber Bragg Grating on Silica and Polymer Optical Fibers

Hwa‐Yaw Tam, Jingxian Cui, Linyue Lu, Dinusha Dilhan Nawarathne
article en
3 citations

Abstract

Optical fiber magnetic field sensors based on magnetostrictive materials have attracted significant interest. However, most existing sensors utilizing optical fibers and magnetostrictive materials have a limited measurement range up to 200 mT, posing a challenge for applications requiring the detection of strong magnetic fields, such as in maglev train systems. In this study, we introduce two magnetic field sensors: one based on a magnetic shape memory alloy-silica fiber Bragg grating (MSMA-SFBG) and the other on an MSMA-polymeric fiber Bragg grating (MSMA-PFBG). These sensors couple magnetic field-induced strain in the MSMA transducer with fiber Bragg gratings (FBGs) inscribed in the silica optical fiber and the polymer optical fiber, respectively. We evaluated the performance of these sensors in terms of sensitivity, measurement range, and saturation magnetic field. The MSMA-SFBG sensor exhibited a linear response with a sensitivity of approximately 2 pm/mT over the magnetic field range from 250 to 550 mT. The MSMA-PFBG sensor demonstrated a sensitivity of 46.02 pm/mT at 400 mT, outperforming Terfenol-D-based magnetic field sensors by about four times in sensitivity. By applying dc bias fields up to 268 mT, the sensitivity of the MSMA-SFBG sensor decreased from 2.01 to 0.56 pm/mT, while the linear measurement range expanded from 250–550 to 50–550 mT. Conversely, the sensitivity of the MSMA-PFBG sensor increased from 2.30 to 18.68 pm/mT at weak magnetic field of 150 mT, although both the measurement range and the saturation magnetic field decreased. These findings suggest that the two proposed MSMA-based magnetic field sensors complement one and other, are well-suited for applications requiring extensive range, and high-sensitivity magnetic field measurements.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Hong Kong Polytechnic University (HK)
University Grants Committee, Innovation and Technology Commission
Openalex Percentile: Top 13%
Advanced Fiber Optic Sensors
2.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.