Design Optimization of a Low-Power and Low-Complexity Digital Driven-Right-Leg Circuit for Active-Electrode Measurement Systems

This article presents a methodology for optimizing the design of a digital driven-right-leg (DRL) circuit for use in improving the common-mode rejection ratio (CMRR) of multichannel active-electrode (AE) biopotential measurement systems operating with dry electrodes. Taking into consideration important design aspects including stability and performance, the proposed methodology aims to maximize the system’s CMRR while minimizing the DRL circuit’s complexity and power consumption. Our design methodology is validated through an ECG measurement system implemented with discrete components. Measured results show that, even with low-resolution data converters, the digital DRL circuit can help boost the overall CMRR by 77.6 dB. With only 6 bits of resolutions for its data converters operating from a full-scale range of 3.3 V, the proposed DRL circuit enables an AE pair, with a poor intrinsic CMRR of 38.26 dB and without the help of any notch filtering, to acquire ECG from dry electrodes with unnoticeable powerline interference.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3554913
Citations
1
Primary Topic
Sensor Technology and Measurement Systems
Type
article
Field-Weighted Citation Impact
1.49

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design Optimization of a Low-Power and Low-Complexity Digital Driven-Right-Leg Circuit for Active-Electrode Measurement Systems

Woradorn Wattanapanitch, Techapon Songthawornpong
1 citations
IEEE Transactions on Instrumentation and Measurement
Sensor Technology and Measurement Systems
1.49
article

Design Optimization of a Low-Power and Low-Complexity Digital Driven-Right-Leg Circuit for Active-Electrode Measurement Systems

Woradorn Wattanapanitch, Techapon Songthawornpong
article en
1 citations

Abstract

This article presents a methodology for optimizing the design of a digital driven-right-leg (DRL) circuit for use in improving the common-mode rejection ratio (CMRR) of multichannel active-electrode (AE) biopotential measurement systems operating with dry electrodes. Taking into consideration important design aspects including stability and performance, the proposed methodology aims to maximize the system’s CMRR while minimizing the DRL circuit’s complexity and power consumption. Our design methodology is validated through an ECG measurement system implemented with discrete components. Measured results show that, even with low-resolution data converters, the digital DRL circuit can help boost the overall CMRR by 77.6 dB. With only 6 bits of resolutions for its data converters operating from a full-scale range of 3.3 V, the proposed DRL circuit enables an AE pair, with a poor intrinsic CMRR of 38.26 dB and without the help of any notch filtering, to acquire ECG from dry electrodes with unnoticeable powerline interference.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Kasetsart University (TH)
National Research Council of Thailand, Royal Golden Jubilee (RGJ) Ph.D. Programme
Affordable and clean energy
Openalex Percentile: Top 19%
Sensor Technology and Measurement Systems
1.49
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design Optimization of a Low-Power and Low-Complexity Digital Driven-Right-Leg Circuit for Active-Electrode Measurement Systems — Woradorn Wattanapanitch, Techapon Songthawornpong · IEEE Transactions on Instrumentation and Measurement (2025) | TGRS Research Map | TGRS