A Wide-Range PDH Frequency-Locking Method for Cavity-Enhanced Raman Detection Based on Fitting Error Signal

The technique of cavity-enhanced Raman spectroscopy (CERS) is important in the field of gas detection. The optical resonator plays a crucial role in the process of cavity enhancement, making it essential to ensure the stability and anti-interference ability of the optical resonator in CERS detection technology. To improve the stability and anti-interference capability of the resonator, we propose a method known as wide-range fitting frequency-locking (WRFFL). By detecting the transmitted power and the system error signal of the Fabry-Perot (F-P) cavity and modeling it with a neural network, a fitting error signal with a wide range and no Trojan operating point is obtained, and the linear dynamic range of the error signal is extended to a maximum of 15 times the original range. Ultimately, a high-stability optical resonator with strong interference resistance is obtained. We conducted locking performance tests on our proposed method in a CERS detection system. The experimental results demonstrate that not only does this method significantly increase the anti-interference ability of the system but also that the locking duration of the resonator reaches 200 min, which is an order of magnitude greater than that of the traditional locking method; the relative stability of the system reaches <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$3.12\times 10^{-9}$ </tex-math></inline-formula>, greatly increasing the static stability of the system. At the same time, the system demonstrates strong robustness and universality under various environmental disturbances, highlighting the reliability and adaptability of the method across diverse application scenarios.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3554911
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Wide-Range PDH Frequency-Locking Method for Cavity-Enhanced Raman Detection Based on Fitting Error Signal

Yongyang Li, Yanguo Guo, Youtong Li, Haozhi Xu et al.
IEEE Transactions on Instrumentation and Measurement
Spectroscopy Techniques in Biomedical and Chemical Research
article

A Wide-Range PDH Frequency-Locking Method for Cavity-Enhanced Raman Detection Based on Fitting Error Signal

Yongyang Li, Yanguo Guo, Youtong Li, Haozhi Xu, Qiang Ren, Chen Chen
article en

Abstract

The technique of cavity-enhanced Raman spectroscopy (CERS) is important in the field of gas detection. The optical resonator plays a crucial role in the process of cavity enhancement, making it essential to ensure the stability and anti-interference ability of the optical resonator in CERS detection technology. To improve the stability and anti-interference capability of the resonator, we propose a method known as wide-range fitting frequency-locking (WRFFL). By detecting the transmitted power and the system error signal of the Fabry-Perot (F-P) cavity and modeling it with a neural network, a fitting error signal with a wide range and no Trojan operating point is obtained, and the linear dynamic range of the error signal is extended to a maximum of 15 times the original range. Ultimately, a high-stability optical resonator with strong interference resistance is obtained. We conducted locking performance tests on our proposed method in a CERS detection system. The experimental results demonstrate that not only does this method significantly increase the anti-interference ability of the system but also that the locking duration of the resonator reaches 200 min, which is an order of magnitude greater than that of the traditional locking method; the relative stability of the system reaches <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$3.12\times 10^{-9}$ </tex-math></inline-formula>, greatly increasing the static stability of the system. At the same time, the system demonstrates strong robustness and universality under various environmental disturbances, highlighting the reliability and adaptability of the method across diverse application scenarios.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Jilin University (CN), China Academy of Engineering Physics (CN)
National Key Research and Development Program of China
Affordable and clean energy
Openalex Percentile: Top 95%
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.