Applicability analysis of new power system protection considering the fault characteristics of DFIG

As the power grid continues to evolve, the emerging power system exhibits "dual high" characteristics, characterized by a high penetration rate of renewable energy sources and a high proportion of power electronic devices. When wind power generators with high permeability are integrated into the distribution network, their intricate magnetic transient behaviors can lead to malfunctions or unintended tripping of existing relay protection schemes. This paper specifically examines the Doubly Fed Induction Generator (DFIG) and assesses its compatibility with distribution network protection strategies. Firstly, the transient characteristics of DFIG during distribution network faults were analyzed, followed by an analysis of its applicability for current protection when connected to the distribution network. Finally, a power grid structure with DFIG was built in PSCAD, and tests were conducted separately for faults at the access point and downstream faults. The results indicate that when a fault occurs in the power line, it may cause the protection range of the lower level quick break protection at the connection location to expand or even exceed the limit. At the same time, due to the low frequency characteristic of the doubly fed fan, it may cause the upper level current differential protection at the connection location to refuse to operate.

Authors

Publication Details

Published
2024-12-27
DOI
https://doi.org/10.1109/eiecc64539.2024.10929303
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Applicability analysis of new power system protection considering the fault characteristics of DFIG

Zhuangzhuang Li, Jixiang Zhao, Yuying Wang, Tao Wang et al.
Power Systems and Renewable Energy
article

Applicability analysis of new power system protection considering the fault characteristics of DFIG

Zhuangzhuang Li, Jixiang Zhao, Yuying Wang, Tao Wang, Лэй Сун, Xiaoran Ma, Hai Huang, Li Ping Wang
article en

Abstract

As the power grid continues to evolve, the emerging power system exhibits "dual high" characteristics, characterized by a high penetration rate of renewable energy sources and a high proportion of power electronic devices. When wind power generators with high permeability are integrated into the distribution network, their intricate magnetic transient behaviors can lead to malfunctions or unintended tripping of existing relay protection schemes. This paper specifically examines the Doubly Fed Induction Generator (DFIG) and assesses its compatibility with distribution network protection strategies. Firstly, the transient characteristics of DFIG during distribution network faults were analyzed, followed by an analysis of its applicability for current protection when connected to the distribution network. Finally, a power grid structure with DFIG was built in PSCAD, and tests were conducted separately for faults at the access point and downstream faults. The results indicate that when a fault occurs in the power line, it may cause the protection range of the lower level quick break protection at the connection location to expand or even exceed the limit. At the same time, due to the low frequency characteristic of the doubly fed fan, it may cause the upper level current differential protection at the connection location to refuse to operate.

Climate action
Openalex Percentile: Top 65%
Power Systems and Renewable Energy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Applicability analysis of new power system protection considering the fault characteristics of DFIG — Zhuangzhuang Li, Jixiang Zhao, et al. · (2024) | TGRS Research Map | TGRS