Single-phase ground fault location method based on REMD-SD

When a single-phase ground fault occurs in a 10kV small-current neutral ungrounded system, the fault current signal is very weak, which makes it difficult to locate the fault after the fault indicator transmits the fault current information to the main station. To solve the above problems, this paper proposes a ground fault location method based on the combination of Robust Empirical Mode Decomposition (REMD) and second-order difference sequences for fault indicators. Firstly, the transient zero-sequence currents of one fifth cycles before and after the fault occurrence time are decomposed by REMD to extract the Intrinsic Mode Functions (IMF) of the first section, and then the second-order difference sequence algorithm is used to obtain the initial concavity and convexity of the fault, and then the fault section localization is carried out according to the difference of the concavity and convexity. The simulation results show that the method has good reliability.

Authors

Institutions

Publication Details

Published
2024-12-27
DOI
https://doi.org/10.1109/ic2ecs64405.2024.10928285
Citations
1
Primary Topic
Advanced Algorithms and Applications
Type
article
Field-Weighted Citation Impact
0.33
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Single-phase ground fault location method based on REMD-SD

Yu Xia, Xiaofeng Zou, Jian Zhou, Gang Wang
1 citations
Advanced Algorithms and Applications
0.33
article

Single-phase ground fault location method based on REMD-SD

Yu Xia, Xiaofeng Zou, Jian Zhou, Gang Wang
article en
1 citations

Abstract

When a single-phase ground fault occurs in a 10kV small-current neutral ungrounded system, the fault current signal is very weak, which makes it difficult to locate the fault after the fault indicator transmits the fault current information to the main station. To solve the above problems, this paper proposes a ground fault location method based on the combination of Robust Empirical Mode Decomposition (REMD) and second-order difference sequences for fault indicators. Firstly, the transient zero-sequence currents of one fifth cycles before and after the fault occurrence time are decomposed by REMD to extract the Intrinsic Mode Functions (IMF) of the first section, and then the second-order difference sequence algorithm is used to obtain the initial concavity and convexity of the fault, and then the fault section localization is carried out according to the difference of the concavity and convexity. The simulation results show that the method has good reliability.

Shanghai Electric (China) (CN)
Climate action
Openalex Percentile: Top 36%
Advanced Algorithms and Applications
0.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Single-phase ground fault location method based on REMD-SD — Yu Xia, Xiaofeng Zou, et al. · (2024) | TGRS Research Map | TGRS